Télécharger Imprimer la page

Bionaire COOL MIST Manuel D'instructions page 8

Publicité

Trouble
• Water Leaks from
Tank.
• Crack in Tank.
• Film on Tank.
• Mist output
minimal to none.
• Filter turns brown. ☛ The filter has absorbed minerals.
S T O R A G E I N S T R u C T I O N S
R E P L A C E M E N T A C C E S S O R I E S
STORAGE INSTRuCTIONS
When not using your humidifier for an extended period of time:
1. Remove filter from unit.
2. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the
unit when storing. Leaving water in the unit may render the unit inoperable for the following season.
3. Place the humidifier in the original carton and store in a cool, dry place.
4. Order your replacement filter for next year's use.
REPLACEMENT ACCESSORIES
If your filter becomes damaged, lost or you would like to replace your filter, replacement filters are available at your
local retailer or Consumer Service at 1-800-253-2764
You can use either of the two filters mentioned on the next page.
If you require a new tank, please contact Consumer Service at 1-800-253-2764 or visit www.bionaire.com
T R O u B L E S H O O T I N G
All manuals and user guides at all-guides.com
TROuBLESHOOTING
Probable Cause
☛ Tank/cap gasket is missing.
☛ Unit tilted or not leveled.
☛ Cap not tight enough.
☛ Tank water is Hot.
☛ Hot water will cause tank to pressurize.
☛ Tanks will crack if hit or dropped.
☛ Mineral deposits.
☛ Filter has not absorbed water.
Solution
✔ Remove tank cap and replace or reposition
gasket.
✔ Place unit on a flat or leveled surface.
✔ Tighten the cap.
✔ Fill with cool water only.
✔ Fill with cool water only.
✔ Handle tank with care. If there is crack in
tank, replace with a new tank.
✔ Clean/disinfect tank as instructed in weekly
cleaning instructions.
✔ Wait 30 minutes for filter to absorb water.
✔ Operate in High setting.
✔ Replace your filter (SW2002-CN) by calling
1-800 -253-2764, or visiting www.bionaire.com .

Publicité

loading