Connect to garage door opener:
• Strip 7/16" (11 mm) of insulation from each set of
wires. Separate white and white/black wires suffi ciently
to connect to the opener quick-connect terminals.
Twist like colored wires together. Insert wires into
quick-connect holes: white to white and white/black to
grey (Figure 10).
Figure 10
Bell Wire
Safety Reversing
Sensor
ALIGNING THE SAFETY REVERSING SENSORS
• Plug in the opener. The indicator lights in both the
sending and receiving eyes will glow steadily if wiring
connections and alignment are correct.
The sending eye amber indicator light will glow regardless
of alignment or obstruction. If the green indicator light in
the receiving eye is off, dim, or fl ickering (and the invisible
light beam path is not obstructed), alignment is required.
• Loosen the sending eye wing nut and readjust, aiming
directly at the receiving eye. Lock in place.
• Loosen the receiving eye wing nut and adjust sensor
until it receives the sender's beam. When the green
indicator light glows steadily, tighten the wing nut.
Connect Wire to Opener
Quick-Connect Terminals
— Finished Ceiling —
Bell Wire
Invisible Light Beam
Protection Area
1. Strip wire 7/16"
(11 mm)
2. Twist like colored
wires together
Safety
3. To release or insert
Reversing
wire, push in tab with
Sensor
screwdriver tip
TROUBLESHOOTING THE SAFETY REVERSING
SENSORS
1. If the sending eye indicator light does not glow steadily
after installation, check for:
• Electric power to the opener.
• A short in the white or white/black wires. These can
occur at staples, or at opener connections.
• Incorrect wiring between sensors and opener.
• A broken wire.
2. If the sending eye indicator light glows steadily but the
receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
3. If the receiving eye indicator light is dim, realign either
sensor.
NOTE: When the invisible beam path is obstructed or
misaligned while the door is closing, the door will reverse.
If the door is already open, it will not close. The opener
lights will blink 10 times. See page 15.
18
7/16" (11 mm)
Red
White
Grey
Quick-Connect Terminals