Installation Method of Insert Module
 Password Function
If the users forgot the password, the password can be cleared by using the following code: 8888. This
universal code will clear the password and all TP08G internal programs. The TP08G will be reset to the
factory settings. Please pay close attention when using it. The password can be the alphabet from A to Z or
the number from 0 to 9. But it must use the function keys F0~F5 to input the password characters. Please
refer to the following table.
Function Key
Numeric Key
0 ~ 9
This key is left direction key and it can
F1
be used to select the position of the
value.
Scrolls in a loop as follows
F2
A→B→C→D→E→F→G→H→I
 Hardware Operation
When the users want to startup TP08G, a 24VDC power is needed. After applying 24VDC power to TP08G, it
will enter into the startup display and then enter the user-designed program. Pressing Esc key and holding on
for 5 seconds can return to system menu. There are five selections in the system menu and are described
below.
SELECTIONS
Use the connection cable (UC-PRG020-12A (2M)) to connect the TP08G serial communication
Download
port RS-232 to a PC. Then use the TPEditor/DIAScreen software to download an application
Program
program to TP08G.
Use the connection cable (UC-PRG020-12A (2M)) to connect the TP08G serial communication
Upload Program
port RS-232 to a PC. Then use the TPEditor/DIAScreen software to upload an application
program from TP08G.
Transfer a program between two TP08G units.
1: Transmit Program ; 2: Receive Program
Copy Program
When transmit programs and data between two TP08G units. Set one TP08G to "Receive
Program" mode and the other TP08G to "Transmit Program" mode. Please use twisted pair wires
to connect the two units via the RS-485 ports.
There are 8 items that used to modify TP08G system settings:
1. Communication protocol: Setting the address of TP08G, and the communication string for
2. Contrast: Adjust the contrast of LCM display screen.
3. Back-light: adjust the automatic turn off time of LCM. Setting range is 00~99 seconds. If set
4. Date and Time: It is used to set the TP08G built-in RTC including year, month, day, hour,
TP08G Settings
5. Buzzer: Used to set the buzzer sound, normal mode or quiet mode.
6. Language Setting: Used to set the displayed language. English, Traditional Chinese, Simplified
7. Password setting: Used to set, enable, and disable the password function. If the password
8. Startup Display: Used to select the TP08G startup display. User can select "user defined" to
Use Method
either RS-232 or RS-485.
to 00, the LCM Back-light will not turn off.
minute, second and week. Also the internal battery capacity display is shown here.
Chinese or user-defined language.
function is enabled, it will require the user to input a password before entering any system
menu. The factory password is 1234.
use the file that designed by TPEditor/DIAScreen software and download to TP08G.
Function Key
Scrolls in a loop as follows
F3
J→K→L→M→N→O→P→Q→R
Scrolls in a loop as follows
F4
S→T→U→V→W→X→Y→Z
It can be a right direction key in the
F5
system menu.
EXPLANAION
Use Method