No.
Name
1
Pump control
2
Protective conductor intermedi-
ate connection
3
Voltage supply/ mains feed-th-
rough terminal
4
Fuse
5
Temperature limiter/ dew point
sensor
6
Reduction channel – connection
for an external system clock
7
Heating/cooling change-over
8
Connection for thermostat
9
Cable guide and strain relief
10
Connection for actuators
Terminal strip
5
6
7
8
10
9
Description
• Potential-free contact for controlling a pump circuit
• Starting and switching-off delay predefi ned with 2 minutes
• Pump protection circuit
- Cyclic triggering of the pump once every 14 days for 1 minute
after the last triggering
• Terminal for the intermediate connection of the protective conductor
of electrical consumers such as e.g. pump (230 V version only)
• Mains connection
• Mains feed-through terminal for the connection of electrical consumers
such as pump (230 V version only)
• Protects the connection strip by interrupting the circuit if the amperage
exceeds a defi ned value for a suffi cient time. Use a fuse suitable for the
respective voltage.
• Switching contact for connecting a temperature limiter or dew point sensors
- The temperature limiter prevents excessive supply temperature of fl oor
heatings via a potential-free contact
- The dew point sensor monitors the system in the cooling mode and
switches it off when dewing is detected
• Transmission of up to two timer signals for time-controlled reduction of the
room temperature to connected thermostats via a potential-free contact
• A room thermostat (No. 8) or an external system clock (No. 6) can be used
as signal source
• Change-over of the complete room-by-room temperature control between
heating and cooling
• Supply of an external signal via potential-free contact
• Forwarding the change-over signal to connected thermostats
• Quick connection of up to 10 thermostats
• Voltage supply for connected thermostats
• Proven, integrated cable guide and strain relief acc. to DIN EN 60730-1
• Voltage supply for connected actuators
• Valve protection function at all outputs (optional)
- Triggering the actuators once every 14 days for 10 minutes after the last
triggering
- Prevents the clogging of valves in times without temperature control
7
2
Device overview
GB