Electric Connection
The constant current terminal +12V (4) must be connected to a cable that also supplies 12V permanently when
the ignition is off (terminal 30 of the on-board network). This terminal serves to save the user settings, time, etc.
The aerial control output (5) supplies a voltage of +12V when the device is switched on. This cable can be used
for the power supply of an electrical aerial, and for the voltage for switching on a vehicle amplifier.
The terminal of the ignition +12V (7) must be connected to a cable that is only live with +12V when the ignition
is on (terminal 15 of the on-board networks).
Do not connect this terminal to continuous current, otherwise the on-board battery could be discharged
when the vehicle is parked for a longer period of time.
Connect the ground connection (8) with the vehicle body.
Adhesive techniques which become ever more common and painted metal parts impair the electric
conductivity. Therefore not every metal part is a suitable earthing point.