3.
Fix the base to the wall. For flat mounting use a minimum
of two screws (DIN 7998) in positions A. For corner-
mounting use screws in positions B or C (Figure 3). To
install a pry-off tamper, use position A or C.
Note:
Using the pry-off tamper has not been evaluated by
UL/cUL.
4.
Wire the detector (see Figures 3 and 7).
UL/cUL installations:
to National Electrical Code, NFPA70, and CSA C22.1,
Canadian Electrical Code Part I, Safety Standards for
Electrical Installations.
5.
Select the desired jumper and DIP switch settings (see
Figure 5). See "Jumper settings" below for more
information.
6.
Remove the blinders and add the stickers, if required (see
Figure 6 for an example).
For ceiling-mount applications that require a 90° coverage
7.
use the SB01 swivel-mount bracket.
Note:
Using the swivel-mount bracket has not been
evaluated by UL/cUL. Ceiling mount application has not
been evaluated by UL/cUL.
8.
Close the cover.
9.
Insert the screw and place the custom insert.
For EN 50131 Grade 3 installations, do not use mounting
position B.
Jumper settings
See Figure 5 for the jumper locations in the detector.
J1: Not used
J3 and J4: Dual loop setting
This sets the alarm and tamper relays. It allows you to connect
the detector to any control panel. Use jumpers 3 and 4. See
Figure 7.
Use Remote Test (RT) to test the detector from the control
panel. The detector will activate the Alarm relay if the test
result is positive, and the AM relay if the test result is negative.
J6: Polarity setting of the control voltage (CV)
On (factory default):
•
The detector is in Day mode (system disarmed) when the
D/N input is connected to GND (terminal 1)
•
The detector is in Night mode (system armed) when the
D/N input is connected to +12 V (terminal 2)
•
The detector is in Walk Test Off mode (LEDs are disabled)
when the WT input is connected to GND (terminal 1)
•
The detector is on Walk Test On mode (LEDs are
enabled) when the WT input is connected to
+12 V (terminal 2)
Off:
•
The detector is in Day mode (system disarmed) when the
D/N input is connected to +12 V (screw terminal 2).
•
The detector is in Night mode (system armed) when the
D/N input is connected to GND (terminal 1).
•
The detector is in Walk Test Off mode (LEDs are disabled)
when the WT input is connected to +12 V (terminal 2).
•
The detector is on Walk Test On mode (LEDs are
enabled) when the WT input is connected to GND
(terminal 1).
4 / 36
All manuals and user guides at all-guides.com
All wiring must be made according
D/N and WT functionality
The D/N input:
•
Controls the LED functionality together with the WT input.
•
Resets the alarm memory
•
Controls the AM relay functionality during the NIGHT
mode together with SW1.
The WT input controls the LED functionality together with the
D/N input.
When the detector is in the Day mode and Walk Test On
mode, the LEDs of the detector can be activated. See "LED
indication" on page 5 for more information.
During the Night mode the LEDs are always switched off.
If a PIR intruder alarm if detected in the Night mode and the
detector switches back to Day mode, the red LED starts
flashing to indicate an alarm in memory.
The alarm memory is reset by switching the detector to Night
mode.
DIP switch settings
Factory default:
5
4
3
2
1
ON
SW 1: When to signal AM (anti-masking) or TF (technical
fault) output
On: Signals AM or TF only when the system is in Day mode
(factory default).
Off: Always signals AM or TF during Day and Night mode.
SW 2: AM sensitivity
On: Advanced AM sensitivity. The detector signals the AM
area masking (factory default).
Off: Standard AM sensitivity. The detector signals the AM area
approaching.
SW 3: Resetting the AM/TF output
On: Auto reset. Resets the AM or TF status 40 seconds after
a PIR alarm.
Off: Authorized reset. Resets the AM or TF status after a PIR
alarm when the system is in Day and Walk Test mode. The
yellow LED will blink quickly. When the system is in Night
status, the yellow LED will turn off and the system is reset
(factory default).
Notes
•
For the advanced setting (SW 2 is On) the source of AM
alarm needs to be removed before AM reset is allowed.
•
If the AM alarm cannot be reset with an auto reset or
authorized reset, disconnect the power supply and
reconnect again.
•
A walk test should be performed to ensure the device
settings are appropriate for its application.
SW 4: Signaling AM or TF output
On: Signals AM on both the AM and Alarm relays. Signals TF
on the AM relay only (EN 50131).
P/N 146279999-2 (ML) • REV H • ISS 11MAR19