OPERATION
1. Put an activated carbon packet (L) in the nozzle. Rinse and clean it under the tap.
Note: fold the filter by half to place it in the cap.
2. Put the nozzle in its place.
3. Open the lid.
4. Pour water in the tank making sure not to exceed the mark. It is about 5 cm from the top.
Note: we recommend using hot water to shorten the time of the cycle.
5. Make sure all the contacts, wires and connections are not wet.
6. The lid of the bottle must be in line with the outlet hole of the tank. Plug the fan power
cord and the main power cord in. Connect the main switch ON. You will notice that the
fan starts working.
DO NOT ALLOW THE UNIT RUNS OUT OF WATER.
7. Turn off the distiller before the unit runs out of water in the kettle. This will prolong the life
of the appliance.
8. However, the distiller will automatically shut off after the cycle is complete. In that case,
press the "RESET" button to restart the distillation.
CLEANING THE TANK
• Fill the tank with 4 litres of hot water.
• Add 1-3 spoonfuls of cleaner (too much acid may damage the material of the tank).
• Leave the lid open, connect the power cord in and press the switch to heat the tank until
the water boils.
• Empty the tank after 15-20 minutes. Then, wash the inside with clean water.
• If there is too much residue to be removed in one go, repeat the process several times
until the inside is completely clean.
• A small amount of residue can cause no damage and you can use the unit safely.
DO NOT ADD ACID TO WATER. The acid will not evaporate, will increase the
acidity cycle after cycle and the it will finally perforate the tank.