Erase/Reset
• To erase users:
NOTE: Erasing a user will erase ALL stored fingerprints. User
does NOT need to reprogram to opener.
1. Open cover and wait until Ready
LED is lit.
2. Enrolled user must slowly and firmly
swipe fingerprint.
3. Press and hold the Enroll button for at
least 6 seconds. The Pass LED and Fail
LED will flash for 15 seconds. During
this time the Resend button is active. After
15 seconds the Enroll and Ready LEDs
will light indicating fingerprints are erased.
The unit will return to Enroll mode.
• To return unit to Factory Reset state:
NOTE: Factory reset state will erase ALL stored fingerprints.
This method should be used ONLY when an enrolled user is not
available as it requires user to reprogram unit to opener.
1. Open cover and wait until Ready
LED is lit.
2. Press and hold the Enroll button
until all LEDs turn off. Release
button.
3. Again press and hold the Enroll
button until the Ready and Enroll
LEDs are lit and not flashing.
Troubleshooting
• If no known enrolled users are available:
— The memory must be erased using the Factory Reset
process.
• If the unit does not recognize a swiped fingerprint:
— Ensure that the Ready LED is lit before you swipe.
— Ensure that fingerprint is swiped correctly (See Tips for
Success).
— Ensure that fingerprint is enrolled.
— Ensure that sufficient pressure is being applied to sensor
strip (do not press too hard).
— Ensure that the sensor and finger are not wet.
• If the unit is in Enroll mode at power up:
— Complete enrollment process for initial user.
— The initial enroll process failed (signaled by a lit Enroll LED
and Fail LED) and must be repeated.
• If enrolling new user and all LEDs flash and unit returns to
Ready mode:
— The memory is full. In order to add new user, the memory
needs to be erased. Refer to Erase User or Factory Reset.
114A3732
• If the unit does not wake:
— A button may be stuck. Press Enroll and Resend buttons to
ensure free movement.
— The batteries may need to be replaced.
1
• If the Fail LED flashes during use:
ENROLL
— The batteries need to be replaced.
SEND
ENROLL
PASS
FAIL
NOTE: If sensor is dirty, user should wipe sensor with a clean
READY
RETRY
finger. It is recommended that the sensor be periodically cleaned
with a lint-free cloth dampened with alcohol.
2
The Battery
3
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
The batteries should produce power for
at least one year. Replace when the Fail
LED flashes during use. The unit
1
requires 4 AAA batteries.
ENROLL
Dispose of old batteries properly.
SEND
ENROLL
PASS
FAIL
READY
RETRY
2
1. Slide cover completely off.
2. Unscrew the two screws and
remove the battery cover.
3. Replace the batteries. Screw the
3
battery cover back on.
4. Slide cover back into place.
Replacement parts:
Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41A6481
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
FOR SERVICE DIAL OUR TOLL FREE NUMBER:
1-800-528-9131
© 2008, The Chamberlain Group, Inc.
All Rights Reserved
Cover
Battery
Cover
Screws
ENROLL
SEND
ENROLL
PASS
FAIL
READY
RETRY