Télécharger Imprimer la page

Grohe Blue Chilled & Sparkling 40 549 Mode D'emploi page 5

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
cylinder, see Figs. [8] to [12].
Connect CO
2
Do not operate the valve on the back of the cooler/
will escape, see Fig. [9].
carbonator as otherwise CO
2
- The valve is only needed when cleaning the cooler/
carbonator.
The faucet has a system-related run-on time of
approx. 1 second each time carbonated water is drawn.
The display in the handle illuminates blue.
®
If the Blue
handle is flashing red and E4 or E6 appears in
the display, the faucet and cooler/carbonator must be
synchronised as follows, see Fig. [13]:
• Press and hold the
and
buttons simultaneously until SE
flashes in the display.
• Press the
button until SE stops flashing.
• Release the
button, C- flashes in the display.
• Keep pressing the
or
button until H- flashes in the
display.
• Press the
button until H- stops flashing.
• Blue
®
handle synchronisation starts; HC appears in the
display and the Blue
®
handle lights up red.
• As soon as the Blue
®
handle lights up green, open the
faucet fully by turning the Blue
®
handle.
• As soon as the Blue
®
handle briefly flashes green, close the
faucet by turning the Blue
®
handle, HC flashes in the
display.
• Confirm the setting by pressing the
appears.
• Release the
button.
The remaining filter capacity is displayed.
Commissioning
Control, see fold-out page II, Fig. [13].
The buttons have the following functions:
Filter replacement reset
Filter size selection
Carbonate hardness adjustment
Display, see Fig. [13].
In the inactive state, the remaining filter capacity is displayed
in percent.
Set the temperature of the cooled, carbonated water on
the cooler/carbonator, see Fig. [14].
Set the filter size, see Fig. [13].
button for filter size selection:
• Press and hold
button once until the currently setted
value (e. g. F1) flashes in the display
• Press the
button and select the required value appears
- F1:
600 liters / 159 gallons
- F2:
1,500 liters / 396 gallons
- F3:
3,000 liters / 793 gallons
- F4:
600 liters / 159 gallons
- F5:
1,500 liters / 396 gallons
- F6:
3,000 liters / 793 gallons
- F7:
- F8:
3,000 liters / 793 gallons
• Press and hold the
button until the required value stops
flashing
• Release the
button:
The remaining filter capacity is displayed.
Note: The various filter cartridges can be ordered at
www.grohe.com.
English
Set carbonate hardness at filter head, see Fig. [15].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column A on fold-out page III.
Display and setting of carbonate hardness on cooler/
carbonator, see table column B on fold-out page III and
Fig. [13].
button for carbonate hardness adjustment:
• Press and hold the
value (e. g. C3) flashes in the display
• Press the
- C4: carbonate hardness
- Factory setting:
C3: carbonate hardness
- C2: carbonate hardness
- C1: carbonate hardness
• Press and hold the
flashing
• Release the
The remaining filter capacity is displayed.
The liter capacity of the filter cartridge varies according to the
water hardness set and the size of the filter cartridge, see table
on fold-out page II.
The cooler/carbonator is set for operation with the 159 gallons
filter cartridge (Prod no.: 40 404 001) at the factory.
button longer, HC
For operation with other filter cartridges the cooler/carbonator
must be set out.
The faucet with cooler/carbonator is now fully installed and
ready for operation.
Maintenance
Resetting filter capacity after changing filter cartridge, see
fold-out page II, Fig. [13].
button for filter replacement reset:
• Press and hold
• Release the
flashing.
• Release the
The remaining filter capacity is reset and then displayed
again.
Restore factory settings, see Fig. [13].
Reset
• Press and hold the
starts flashing in the display.
• Release the
40 404 000
The remaining filter capacity is displayed.
40 430 000
40 412 000
Important:
40 404 001
Risk of damage!
40 430 001
Always disconnect the power supply and interrupt
40 412 001
the CO
on the system. The plug-in connector can then be
40 547 001
disconnected, see fold-out page II, Figs. [6] and [7].
(Activ carbon)
Inspect and clean all components and replace if necessary.
Assemble in reverse order.
Cleaning cooler/carbonator
For hygienic and healthy reasons, the cooler/carbonator
must be cleaned once a year. Cleaning must be
performed before changing the filter cartridge, in order to
prevent contamination of the replacement filter cartridge.
Note: The cleaning kit (Prod. no.: 40 434 001) and the
accompanying adapter (Prod. no.: 40 694 000 or 40 699 000)
could be ordered at www.grohe.com.
button once until the currently setted
button and select the required value:
9
(bypass 3)
10 - 24
(bypass 2)
25 - 29
(bypass1)
30
(bypass 0)
button until the setted value stops
button.
button until rF flashes in the display.
button and press again until rF stops
button.
buttons to factory settings:
buttons simultaneously until PA
buttons.
supply before carrying out maintenance work
2
2

Publicité

loading