Tools and Parts
Gather the required tools and parts for correct high altitude
conversion.
Tools needed
■
Flat-blade screwdriver
³⁄₃₂" (#0 [2.0 mm]) flat-blade screwdriver (screwdriver shaft
■
must be a minimum of 2" [5.1 cm] long)
■
Adjustable wrench
■
7.0 mm nut driver
■
7.0 mm wrench
■
®†
T10 Torx
adapter
Parts needed
Cooktops using Natural or LP gas can be converted for use at
elevations above 6,560 ft (1999.5 m).
For models KCGS550ESS, KCGS556ESS, KCGS950ESS, and
KCGS956ESS use the following parts:
Natural Gas Units
■
High altitude orifice package (W10679118)
■
Conversion instructions (W10698219A)
LP Gas Units
■
High altitude orifice package (W10679116)
■
Conversion instructions (W10698219A)
For all other models use the following parts:
Natural Gas Units
■
High altitude orifice package (W10679113)
■
Conversion instructions (W10698219A)
LP Gas Units
■
High altitude orifice package (W10679114)
■
Conversion instructions (W10698219A)
IMPORTANT: High altitude conversions must be done by a
qualified installer. Before proceeding with conversion, shut off the
gas supply to the cooktop prior to disconnecting the electrical
power.
WARNING
This conversion kit shall be installed by a
qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation is
not proper and complete until the
operation of the converted appliance is
checked as specified in the
manufacturer's instructions supplied with
this kit.
†®TORX is a registered trademark of Acument Intellectual Properties, LLC.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Convert for High Altitude
1. Turn manual shutoff valve to the closed position.
A
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug cooktop or disconnect power.
Convert Gas Pressure Regulator (LP Gas Units Only)
IMPORTANT: If you are converting the cooktop for use with LP
gas, the gas pressure regulator must be converted. See the "LP
Gas Conversion Instructions" for proper regulator conversion.
3. If the burner grates are installed, remove them.
B
C