Technical specifications
Mains voltage:
Module consumption:
Temperature:
Relative humidity:
Load power:
Dimensions:
Wiring
Temporary
pushbutton for
Bp temporaire
module
pour réglage
configuration
du micromodule
Line controlled
L
by twilight
N
sensor, ...
Module configuration
Important: Before starting any configuration, short
press 23 times to unblock the module. The module
will lock again automatically after 6 hours. It can be
locked immediately by using a 21 short presses
sequence.
Switch-off time: All configurations are stored in the
case of blackout. The switch-off time can be
configured from a minimum of 4 to a maximum of 9
hours by means of short presses sequences (see
table). The value is preset to 5 hours by default.
Shift of the calculated middle of the night: The
middle of the night can be shifted forwards from 0 to 2
hours (see table). The default shift value is preset to 1
hour.
Demo mode: The product can be tested by
accelerating the internal clock (x 1440) in demo
mode. In this mode, a 24-hour day is simulated in 1
minute.
Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C
For technical information, go to www.yokis.com or call:
Customer Service: +39 011.23.39.810 - Export Dept. Phone: +39 011.24.00.250/256 -
WARRANTY: In addition to the warranty required by law, this product is guaranteed for 5 years from date of manufacture. The material must be used
according to the instructions provided and for its intended use. Faults must not be caused by deterioration or accidents resulting from negligence, ano-
malous use or incorrect installation. In all cases, the warranty only includes replacement of faulty products. No compensation for loss or damage may be
claimed.
DS1054-008A
230V~ +/-15% - 50Hz
< 1 W
from -30°C to +70°C
from 0 to 99%
600VA max., 230VAC
48 x 32 x 20 mm
[1.78 x 1.26 x 0.79"]
Controlled
light
Luminaire
Fax: +39 011.24.00.296
COMPATIBLE LOADS
Resistive
230V incandescent light bulbs
230V halogen light bulbs
Radiating elements and convectors
Inductive
Low voltage light bulbs (12V) with
ferromagnetic transformer
Low voltage light bulbs (12V) with toroidal transfor-
mer
Generic motor, aerator or fan > 11VA
Fluorescent light bulbs with ferromagnetic
ballast
Metal halide light bulbs
Capacitance
Low voltage light bulbs (12V) with electronic trans-
former
Standard energy-saving light bulbs
Dimmable energy-saving light bulbs
Fluorescent light bulbs with electronic ballast
230V LED light
12V LED with dimmable converter
Window shutter motors
At 230V or 12/24V
(1)
1000W max.
Number of
pressess (1)
10
no switch-off
11
4 hours
12 (*)
5 hours
13
6 hours
14
7 hours
15
8 hours
16
9 hours
Move the middle of the night
17
no move
18 (*)
1 hour
19
2 hours
21
Lock configurations
23
Unlock configurations
25
Reset default settings
26 (*)
Demo mode off
27
Demo mode on
(1) Short presses sequences on a temporarily connected
pushbutton.
(2) Confirmation reply by flashing after short presses
sequence.
(*) default value.
P6
Power: Max. 2000W
Power: Max. 500VA
Power: Max. 500VA
Time
Switch-off time
(1)
(1)
Reply (2)
10 flashes
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
9 flashes
1 flash
3 flashes
2 flashes
6 flashes
7 flashes