IO-Link Data Dictionary
10.05.11.00014
IO-Link Implementation
Vendor ID
Device ID
SIO-Mode
IO-Link Revision
IO-Link Bitrate
Minimum Cycle Time
Process Data Input
Process Data Output
Process Data
Process data In
PD in byte 0
Vacuum High-Byte
Vacuum Low-Byte
Switching Point 1 /
PD in byte 1
Switching Point 3
Switching Point 2
Process data Out
Apply atmosphere
PD out byte 0
Apply vacuum
not used
ISDU Parameters
ISDU Index
Subindex
dec
hex
dec
Identification
Device Management
16
0x0010
0
Vendor name
17
0x0011
0
Vendor text
18
0x0012
0
Product name
Product ID
19
0x0013
0
Product text
20
0x0014
0
21
0x0015
0
Serial number
Hardware revision
22
0x0016
0
Firmware revision
23
0x0017
0
Unique device identification
240
0x00F0
0
250
0x00FA
0
Article number
252
0x00FC
0
Production date
Device Localization
24
0x0018
0
Application specific tag
25
0x0019
0
Function tag
26
0x001A
0
Location tag
242
0x00F2
0
Equipment identification
246
0x00F6
0
Geolocation
NFC web link
248
0x00F8
0
249
0x00F9
0
Storage location
253
0x00FD
0
Installation date
Parameter
Device Settings
Commands
2
0x0002
0
System command
Access Control
90
0x005A
0
Extended device access locks
Pin-Code NFC
91
0x005B
0
Process Settings
72
0x0048
0
Function of input PD1.0
75
0x004B
0
Output filter
Permissable evacuation time
107
0x006B
0
Switchpoint 1
Switch Point 1 - Upper threshold
1
SP1 / FH1
60
0x003C
2
Switch Point 1 - Lower threshold
rP1 / FL1
1
Switch Point 1 - Logic
2
Switch Point 1 - Mode
61
0x003D
Switch Point 1 - Window hysteresis
3
Bits
0..7
2..7
0
1
Bits
0
1
2..7
Parameter
Size
Value Range
0...32 bytes
0...32 bytes
0...32 bytes
0...32 bytes
0...32 bytes
9
bytes
2
bytes
4
bytes
20
bytes
14
bytes
3
bytes
1...32 bytes
1...32 bytes
1...32 bytes
1...64 bytes
1...64 bytes
http://...
1...64 bytes
https://...
1...32 bytes
1...16 bytes
5, 129, 131, 165, 167, 168,
1
byte
1
byte
2
bytes
1
byte
2
bytes
2
bytes
0-9999
999 >= SP1 > rP1
2
bytes
SP1 > SP2
999 >= FH1 > FL1+Hy1
2
bytes
FH1 > FH2
1
byte
1
bytes
0 <= Hy1 < FH1-FL1
2
bytes
234 (0xEA)
100352(0x18800)
no
1.1
38.4 kBit/sec (COM2)
Access
Remark
ro
System vacuum [mbar]
ro
System vacuum [mbar]
Vacuum is above SP1 & not yet below rP1, vacuum is between FH1 & FL1 in Window Mode respectively part detached SP3 (switch
ro
function with ISDU 72)
ro
Vacuum is above SP2 & not yet below rP2 respectively vacuum is between FH2 & FL2 in Window Mode
Access
Remark
wo
Apply atmosphere
wo
Apply vacuum
wo
not used
Access
Default Value
-
ro
J. Schmalz GmbH
-
ro
Innovative Vacuum Solutions
-
ro
LQEi
-
ro
LQEi
-
ro
LQEi 8 24V-DC 3/2 IMP
-
ro
000000001
-
ro
00
-
ro
1.00
-
ro
-
-
ro
10.05.11.00014
-
ro
N22
-
rw
***
-
rw
***
-
rw
***
-
rw
***
-
rw
***
rw
https://myproduct.schmalz.com/#/
-
rw
***
-
rw
***
wo
-
169
0-255
rw
0
0-999
rw
0
0-1
rw
0
0-999
rw
10
rw
0
rw
750
rw
600
rw
0
0 - 1
3
2, 3
rw
140
rw
J. Schmalz GmbH
Johannes-Schmalz-Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403-0
www.schmalz.com
info@schmalz.de
2,5 ms
2 bytes
1 byte
Remark
Manufacturer designation
Vendor text
Product name
Product variant name
Order-code
Serial number
Hardware revision
Firmware revision
Unique ID
Order-number
Date code of production (month and year, month is letter coded
User string to store location or tooling information
User string to store location or tooling information
User string to store location or tooling information
User string to store identification name from schematic
User string to store geolocation from handheld device
Web link to NFC app (base URL for NFC tag)
User string to store storage location
User string to store date of installation
0x05 (dec 5): Force upload of parameter data into the master
0x81 (dec 129): Reset application
0x83 (dec 131): Back to box
0xA5 (dec 165): Calibrate vacuum sensor
0xA7 (dec 167): Reset erasable counters
0xA8 (dec 168): Reset voltages min/max
0xA9 (dec 169): Reset vacuum min/max
Bit 0: NFC write lock
Bit 1: NFC disable
Bit 2: Not used
Bit 3: Not used
Bit 4: IO-Link event lock (suppress sending IO-Link events)
Bit 5-7: Not used
PIN for writing data from NFC app
0 = SP1
1 = SP3
Unit: 1ms
Unit: 1ms,
no evacuation time warning if set to 0
Unit: 1mbar
Unit: 1mbar
0 = NO
1 = NC
2 = Window Mode
3 = Two-Point Mode
Unit: 1mbar
LQEi
03.08.2023