Wiring Diagram
The P5611OT thermostat can be used with any one-stage heating or air-conditioning
system.
NO – switched contact
COM – contact for the switch
L – 230 V AC power connection
N – neutral conductor
N/O
COM
ON
Pump/Motorised Valve Wiring Diagram
NO
Pump/valve
Floor Heating Wiring Diagram
NO
connected
device
L
N
230 V~
50–60 Hz
16 (5) A
COM
L
COM
L
N
N
L
N
N
L