4.1 Connecting the induction loop
Connect the ends of the loop wires to the terminals (10) on the back of the amplifier.
Single loop
Please note the following information:
• The loop amplifier must be located outside of the loop.
• Twist the cable section between the amplifier and the loop (feed cable to the loop) to
prevent interference.
• Use a suitable measurement device (e.g. ohm meter) to make sure that the loop doesn't
have a short-to-ground (no damage on the insulation of the loop wiring)!
• The distance from the loop level to the normal listening level should be approx. 1.20 m
to 2.00 m.
4.2 Notice for 19" rack installation
5.1 Verstärker konfigurieren
14 English
Double loop
Remove the 3 screws on the forward area of the left and right
sides of the PROLOOP C.
Use the removed screws to fix the 19" rack mounting pla-
tes on the forward areas of the left and right side of the
PROLOOP C.
Unbalanced
Shield / GND
Signal to Pin 2 or 3
Balanced
Shield / GND
Signal to Pin 2 and 3