1-4. INSTALLATION DIAGRAM
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Drain hose *1
(2) Remote controller holder
(3) Screws for (2) 3.5 × 16 mm (Black)
(4) Pipe cover
(5) Band
(6) Battery (AAA) for (12)
(7) Indoor unit mounting bracket
(8) Fixing screws for (7) 4 × 25 mm
(9) Wood screw for indoor unit fixation
(10) Washer of (9)
(11) Felt tape (For left or left-rear piping)
(12) Wireless remote controller
Note:
*1 The Drain hose is connected to the unit.
FIELD-SUPPLIED PARTS
(A) Indoor/outdoor unit connecting wire *2
(B) Extension pipe
(C) Wall hole sleeve
(D) Wall hole cover
(E) Pipe fixing band
(F) Fixing screw for (E) 4 × 20 mm
(G) Piping tape
(H) Putty
Drain hose
(J)
(or soft PVC hose, 19/32 in. (15 mm) in-
ner diameter or hard PVC pipe VP16)
(K) Power supply cord *2
Note:
*2 Place indoor/outdoor unit connecting wire (A) and power supply cord (K) at least 3 ft. (1 m) away from the TV antenna wire.
<KJ09/12>
*3 4 in. (100 mm) or more when front
and sides of unit are clear
*4 When any 2 sides of left, right
and rear of unit are clear
Unit: inch
31-1/2
5-15/16
19-11/16
Air inlet
1-9/16
Air outlet
×
2-3/8
13/16
slot
Units should be installed by licensed contractor
according to local code requirements.
Note:
• The dimensions indicated in the arrows (
show the required space to guarantee performance of
the air conditioner. Install the outdoor unit where the
maximum possible space can be provided, considering
later relocation, services, or repairs.
• The cooling/heating performance and the efficiency of
power usage may fall about 10% at the place where short
cycle is likely occur due to poor ventilation. Installing the
air outlet guide (optional) can improve performances.
• If air from the outlet blows against the wall, it may cause
stains on the wall.
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and make the fan stop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent
the outdoor unit and/or the grounds from being wet by drain water or damaged by frozen drain water.
EN-3
1
1
2
1
2
2
1
5
4
4
1
Obstacles above
1
It's possible to
install an obstacle
to the following
area.
1-37/64 in.
1
(40 mm) or
30° or less
less
1
1
1
2 to 5
2 to 5
1
1
1
1
(J)
(K)
Unit: mm
800
150
500
Air inlet
40
Air outlet
×
2-10
21 slot
Do not take in the outlet air
) above
discharged by other units directly.
<KJ15/18>
*5 20 in. (500 mm) or more when front
and sides of unit are clear
*6 When any 2 sides of left, right
and rear of unit are clear
Unit: inch
33-1/16
6-7/8
19-11/16
Air inlet
Air outlet
2-3/8 × 13/16 slot
1-9/16
Use the wall hole sleeve (C) to prevent
indoor/outdoor connecting wire (A) from
contacting metal parts in the wall and
to protect the wiring from rodents.
Wall hole cover (D)
Indoor
Seal the wall hole
unit
gap with putty (H).
Wall hole
Attach the pipe
sleeve (C)
to wall with pipe at-
tachment strap (E).
Pipe attachment
Cut off the
strap (E)
extra length.
Attachment screw (F)
After the leak test, apply
insulating material tightly so
that there is no gap.
Cover the connection part
with tape to prevent water
from leaking.
When the piping is to be at-
tached to a wall containing
metals (tin plated) or metal
netting, use a chemically treat-
ed wooden piece 25/32 in.
(20 mm) or thicker between
the wall and the piping or wrap
of insulation vinyl tape around
the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump down before remov-
ing the old air conditioner.
Remake flare according to the
dimension for new refrigerant.
(K)
(J)
Unit: mm
840
175
500
Air inlet
Air outlet
2-10 × 21 slot
40

Publicité

loading

Ce manuel est également adapté pour:

Mfz-kj09naMfz-kj15naMfz-kj18naMfzkj15nau1Mfz-kj18na-u1