Télécharger Imprimer la page

Desa 125-R Manuel D'utilisation page 7

Masquer les pouces Voir aussi pour 125-R:

Publicité

Les langues disponibles

Les langues disponibles

OPERATING
INSTRUCTIONS
Continued
SHUTTING OFF HEATER
• For short periods of time, turn the main burner
off by turning control knob clockwise to the
PILOT position.
• For extended periods of non use, turn appli-
ance completely off by turning control knob
clockwise to the PILOT position, press knob
slightly, then turn knob fully clockwise to
the OFF position. Note: For propane/LP gas
models, also turn off gas supply cylinder.)
PILOT BURNER ADJUSTMENT
1. Remove pilot adjustment cap. The pilot adjust-
ment cap is a slotted screw located in front
of the PILOT designation stamped on top of
valve body just below control knob.
2. Adjust pilot key to provide properly sized
flame. Rotate the key clockwise to decrease
flame or counterclockwise to increase flame.
3. Replace pilot adjustment cap.
MAINTENANCE
WARNING:
• Never attempt to service
heater while it is connected to
propane supply, operating or
hot. Severe burns can occur.
• Keep heater clear and free
from combustible materials,
gasoline and other flammable
vapors and liquids.
• Do not block the flow of com-
bustion or ventilation air.
1. Keep heater clean. Clean heater annually or as
needed to remove dust and debris. If heater is
dirty or dusty, clean heater with a damp cloth.
Use household cleaners on difficult spots.
2. Inspect heater before each use. Check connec-
tions for leaks. Apply mixture of liquid soap
and water to connections. Bubbles forming
show a leak. Correct all leaks at once.
3. Inspect hose/regulator assembly before each
use. If hose is highly worn or cut, replace.
4. Have heater inspected yearly by a qualified
service agency.
114248-01B
www.desatech.com
Get other manuals https://www.bkmanuals.com
SPECIFICATIONS
Propane/LP Model 125-R
Rating
125,000 Btu/Hr (131,882 kj)
Fuel
Propane Vapor Only
Fuel Consumption per Hour
5.17 liters (1.3 gallon)
2.6 kg (5.8 pounds)
Supply Pressure To Regulator (for input adjustment)
Maximum
1380 kPa (200 psi)
Minimum
138 kPa (20 psi)
Manifold Pressure
2.3 kPa (9.5 inches W.C.)
Weight
Heater
17.69 kg (39 lbs)
Shipping
20.86 kg (46 lbs)
Size - L x W x H
40.6 x 45.7 x 109.2 cm
(16 x 18 x 43 inches)
Min Temperature
-29 °C (-20° F) Surrounding
Air Temperature
Natural Gas Model 125-RN
Rating
125,000 Btu/Hr (131,882 kj)
Fuel
Natural Gas Only
Fuel Consumption
per Hour
3.5 m
Manifold Pressure 1.5 kPa (6 inches W.C.)
Weight
Heater
17.69 kg (39 lbs)
Shipping
20.86 kg (46 lbs)
Size - L x W x H
40.6 x 45.7 x 109.2 cm
(16 x 18 x 43 inches)
Min Temperature
-29 °C (-20° F) Surrounding
Air Temperature
(125 ft
)
3
3
7

Publicité

loading

Ce manuel est également adapté pour:

125-rn