OPERATING INSTRUCTIONS:
The lowest handle has a degree scale and it controls the thermostatic element.
The button on the handle blocks the rotation at 38°C (100°F) for safety and anti scald purposes.
By pressing the button, the handle can be turned further obtaining higher water temperatures up to
approximately 55°C (131°F).
ADJUST TEMPERATURE LIMIT STOP:
To increase or decrease the maximum temperature of hot water proceed as follows:
•
Turn the thermostatic handle counter clockwise to the stop
•
Take off the cap and the fixing screw of the thermostatic handle then the handle itself
•
Turn the thermostatic cartridge pin clockwise (for colder water) or counter clockwise (for hotter water) till
the temperature desired
•
Reassemble the thermostatic handle, keeping attention to have the button in correspondence of the stop
SERVICE INSTRUCTIONS:
The thermostatic mixer is set at the factory at the temperature of 38°C (100°F).
If the temperature, of the mixed water, should not result at 38°C (100°F), proceed as follows:
•
By keeping the temperature handle upward, take off the cap and the fixing screw of the thermostatic han-
dle then the handle itself
•
Remove the white stop sleeve
•
Turn the thermostatic cartridge pin clockwise (for colder water) or counter clockwise (for hotter water) till
the temperature of water of 38°C (100°F) is obtained
•
Reassemble the white stop sleeve as shown in the picture below
•
Reassemble the handle, keeping attention to have the button upward
CONDITION OF USE:
Product for use with shower heads rated at 9.5 L/min (2.5 gpm) or higher
INSTALLAZIONE / INSTALLATION