Télécharger Imprimer la page

DITEC REM 25 Mode D'emploi page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1. ELECTRICAL CONNECTIONS
+
-
S
P
1
0
1.1 OUTPUT
OUTPUT
FUNCTION
+ / -
POWER SUPPLY 24 V=
C-NA
OPENING
C-NA
OPENING AND SAFETY
Only Transit 95/97
C-NC
REVERSAL SAFETY
C-NC
STOPPING SAFETY
RC
COMMON RELAY
OPERATION
P
RANGE SWITCHING
Only Transit 95/97
S
SYNCHRONISM
2.
REGULATIONS
T1
Long range. Trimmer T1 regulates the long range of the REM. The long range is coupled to the opening
command and is to be regulated according to the need for detecting people.
T2
Short range. Trimmer T2 regulates the short range of the REM. The short range is coupled to the safety
command and is to be regulated so as not to detect the door jamb or the wall.
NOTE: the long range and the short range of the REM change like the colors change as shown in the table.
Regulations
T1 LONG RANGE
T2 SHORT RANGE
DITEC S.P.A - IP1274 - REM
All manuals and user guides at all-guides.com
RC
T1
NC
C
NA
Connect "+" to terminal 1 and "-" to terminal 0 of the E.B.
Connect C to terminal 1 and NA to terminal 3 of the E.B.
When the radar detects the approaching person or object, the door opens.
Connect C to terminal 1 and NA to terminal 25 of the E.B. when
the door is closed so that it starts to open. During the opening
and closing operations, a 1-25 command stops the door. The
door opens at the end of the command.
NOTE: In the presence of objects or walls near the door, reduce
the range of the REM by connecting P to terminal 26 of the E.B.
Connect C to terminal 1 and NC to terminal 8 of the E.B. It
reverses the motion (reopening) during the closing operation.
Connect C to terminal 1 and NC to terminal 9 of the E.B. It
makes the door stop. At the end of the command the door
continues the previously interrupted operation.
If two or more REMs are connected to the same automatic system
for running the same command (should the installation be simpler),
it is possible to connect the RC terminals to one another. In this
manner it will suffice to connect the NC/C/NA terminals of only
one REM to the board of the automatic system.
Connect P to terminal 26 of the E.B. When the door is closed,
the REM is in long range status (T1). The REM switches to short
range (T2) from the moment the door begins to open to when it
closes.
NOTE: if you connect P to terminal 0 of the E.B. the REM al-
ways stays in short range status (T2).
If two or more REMs detect the same crossing area, connect
terminals S to one another and set the Dip switches in sequence
to avoid any interference.
DIP1
1 2
WHITE
min
0.6 m
0.6 m
TX
T2
DESCRIPTION
DIP1
DIP2
DIP2
1 2 3 4
1 2
1 2 3 4
REM1
REM2
GREY
max
min
3.5 m
0.3 m
1.7 m
0.2 m
4
DIP1
RX
DIP2
DIP1
DIP1
DIP2
1 2
1 2 3 4
1 2
REM3
REM4
BLACK
min
max
2.5 m
0 m
0.8 m
0 m
DIP2
1 2 3 4
max
1.2 m
0.5 m

Publicité

loading

Produits Connexes pour DITEC REM 25

Ce manuel est également adapté pour:

Rem 100