Figure. 11. Disassembly of the inner glass and revision of the stove
CONNECTING THE DEVICE TO THE GAS INSTALLATION
NOTE!!!
Depending on the type of the NG / LPG, an appropriate nozzle must be mounted in the control
burner block. As standard, the unit is equipped with a burner adapted to natural gas (NG). In
the case of connecting the stove to an LPG-powered system, please contact your dealer for
replacement of the main burner with the right one.
WARNING!!!
The main burner module used in gas appliances in the stove consists of two parts connected to
the outlet of the GV60 controller by a tee.
NOTE!!!
All activities associated with connecting the device to the gas installation should be carried
out with the power disconnected. The stove installation can only be done by a qualified fitter/
technician with appropriate licences.
NOTE!!!
It is absolutely forbidden to use open fire during the installation process of the gas stove.
Failure to follow instructions could result in fire or explosions, causing severe damage, bodily
injury or even death.