Télécharger Imprimer la page

Sub-Zero 424G Mode D'emploi page 5

Publicité

Les langues disponibles

Les langues disponibles

MODEL 424G / 424FSG SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit,
servicing only this appliance is required. A ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause
interruption of operation.
IMPORTANT NOTE:
The electrical outlet must be placed so
the grounding prong is to the right of the thinner blades.
The outlet must be flush with the back wall.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
LEFT SIDE
OF OPENING
1
2"
15
/
"
2
(51)
(394)
3"
(76)
FLOOR
Electrical supply location.
All manuals and user guides at all-guides.com
115 VAC, 60 Hz
15 amp
3-prong grounding-type
Preparation
To operate properly, the door must open a minimum of 90°.
Use a minimum 3"
filler in corner installations to assure
(76)
a 90° door opening.
Uncrate the unit and inspect for damage. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket, hardware and the leveling legs which hold the
wood base to the bottom of the unit.
|
subzero.com
5

Publicité

loading

Ce manuel est également adapté pour:

424fsg427g427rgWs-30