Chauffage infrarouge à bouteille de gaz (25 pages)
Sommaire des Matières pour Mr. Heater PA60QFAV
Page 1
OPERATING INSTRUCTIONS AND OWNERÊS MANUAL FORCED AIR PROPANE Model # PA60QFAV, CONSTRUCTION HEATER PA85QFAV Featuring NEW QUIET BURNER TECHNOLOGY PA125QFAV READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
Page 2
TWITTER: Find us on twitter 125FAV PARTS ................9 YOUTUBE: There are now informational videos WARRANTY ................12 on YouTube. WEBSITE: Mr. Heater's full line of product are now at LANGUAGES WWW.MRHEATER.COM English ................1-12 Spanish .................. 1-12 French ................... 1-12 Mr.
Page 3
Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 4
19. Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 5
Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 6
Wait 5 minutes. purchase, the nature of the problem and proof of purchase. Restart following "Start" procedure. Out-of-warrranty products will be repaired with a charge for parts and labor. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 7
AIR TEMPERATURE - 85,000 BTU/HR (33.4 kW) 125,000 BTU/HR (49.1 kW) 3 Cylinders 100# (45.4kg) 2 Cylinders 100# (45.4kg) 1 Cylinders 100# (45.4kg) AIR TEMPERATURE - AIR TEMPERATURE - Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 8
WIRING DIAGRAMS PA60QFAV & PA85QFAV WIRING DIAGRAMS PA125QFAV Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 9
Forced Air Propane Construction Heater • Model PA60QFAV REF.# ITEM# DESCRIPTION QTY. REF.# ITEM# DESCRIPTION 27925 Handle,carry,35k 23276 Ignition/relay module 27443 Guard,rear,assy,60k 23045 Ignition brkt 40701 Motor mounting Brkt. 27452 Fuel tube assembly 21652 Motor assembly 27453 Plastic insert 26086...
Page 10
Radiationshield assembly 27489 Variable valve assembly 27449 Outer shell 27285 Main gas valve 40900 Orifice holder 26127 Fitting, male connector 27487 Orifice 27493 Hose and Regulator (10' Long) Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 11
Bracket, ignition relay 40905 Fitting, gas inlet 23276 Board, spark ignition 21036 Power cord assembly 25026 Elevation knob 26223 Strain Relief Bushing 27493 Hose and Regulator (10' Long) Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 12
If a part is damaged or missing, call our Technical Support Department at 800-251-0001. Address any Warranty Claims to the Service Department, Mr. Heater, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135. Include your name, address and telephone number and include details concerning the claim.
Page 13
INSTRUCCIONES DE USO Y MANUAL DEL USUARIO CALENTADOR A PROPANO DE AIRE Modelo # FORZADO PARA CONSTRUCCIÓN PA60QFAV, PA85QFAV Presentamos la NUEVA TECNOLOGÍA DE PA125QFAV QUEMADOR SILENCIOSO LEA CUIDADOSAMENTE LAS INSTRUCCIONES: lea y siga todas las instrucciones. Consérvelas en un lugar seguro para futura referencia. No permita que nadie que no haya leído estas instrucciones arme, encienda, ajuste o use el calentador.
Page 14
SOLICITADOS ................7 DIAGRAMAS DE CABLEADO ............8 Con el fin de proporcionar el mejor servicio posible Mr. Heater ahora se le está dando más formas de REPUESTOS 55FAV ..............9 ponerse en contacto con nosotros REPUESTOS 60FAV ..............9 FACEBOOK: Encuéntrenos en facebook...
Page 15
Calor directo significa que la totalidad de los productos de combustión ingresa en el espacio calefaccionado. Si bien este Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 16
Normas para el almacenamiento y el suministro de gases licuados del petróleo, ANSI/NFPA 58 y CSA B149.1, Código de instalación de gas natural y propano. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 17
Indíqueles que ventilen el edificio y el área antes de volver a ingresar. El personal de servicio capacitado y adecuado debe reparar la fuga, controlar la existencia de otras fugas y luego volver a encender la aplicación. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 18
Para ajustar la elevación del tubo de combustión, gire la perilla del tornillo de ajuste hacia la izquierda, y eleve el tubo de combustión hasta la posición deseada. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 19
28,000 38,000 49,000 TEMPERATURA DEL AIRE: 85,000 BTU/HR (33,4 kW) 125,000 BTU/HR (49,1 kW) Utilizar extracción de líquido y un vaporizador TEMPERATURA DEL AIRE: TEMPERATURA DEL AIRE: Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 20
DIAGRAMA DE CABLEADO WIRING DIAGRAMS PA60QFAV & PA85QFAV WIRING DIAGRAMS PA125QFAV Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 21
Calentador de propano a aire forzado para construcción • Modelo PA60QFAV REF.# ITEM# DESCRIPTION QTY. REF.# ITEM# DESCRIPTION 27925 Manija Módulo de ignición/relé 23276 Cubierta posterior 27443 Soporte de ignición 23045 Soporte, montaje del motor 40701 27452 Tubo de combustible...
Page 22
Válvula, variable 27489 27449 Cascara externa Válvula, gas, principal 27285 40900 Titular de orificio 26127 Adaptador, conector macho 27487 Orificio 27493 Mangueras y el regulador (10 'Long) Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 23
Módulo de ignición/relé 40905 Adaptador, conector macho 25026 Perilla de elevacion Cable de alimentación 21036 Casquillo de alivio de la tensión 26223 Mangueras y el regulador (10 'Long) 27493 Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 24
Mr. Heater, Inc. se reserva el derecho de realizar cambios en cualquier momento, sin aviso u obligación, en los colores, las especificaciones, los accesorios, los materiales y los modelos.
Page 25
GUIDE D'UTILISATION ET MANUEL DU PROPRIÉTAIRE APPAREIL DE CHAUFFAGE AU PROPANE Modèle # À AIR PULSÉ POUR CHANTIER DE PA60QFAV, CONSTRUCTION PA85QFAV Avec la NOUVELLE TECHNOLOGIE DE PA125QFAV BRÛLEUR SILENCIEUX LISEZ SOIGNEUSEMENT LES INSTRUCTIONS : Lisez et observez toutes les instructions. Conservez ces instructions dans un endroit sécuritaire pour vous y référer ultérieurement.
Page 26
INSTRUCTIONS DE FONCTIONNEMENT ........6 WWW.MRHEATER.COM ENTRETIEN ................. 6 Afin de fournir le meilleur service possible Mr. Heater est maintenant TABLEAU DE DIMENSIONS ET CONTENANCES ......7 de vous donner plus de moyens pour entrer en contact avec nous: SCHÉMAS DE C˜BLAGE ............. 8 FACEBOOK: Retrouvez-nous sur facebook PI˚CES POUR LE MOD˚LE 55FAV ..........
Page 27
à la sécurité et de Le fonctionnement à feu direct de cet appareil signifie que tous les avertir des dangers inhérents. les produits de combustion se retrouvent dans l'air ambiant. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 28
à l'entreposage et à la manutention des produits de pétrole liquéfiés ANSI/NFPA 58 et CSA B149.1 du Code d'installation du gaz naturel et du gaz propane. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 29
Assurez-vous qu'ils aient aéré l'immeuble avant d'y retourner. Le personnel d'entretien expérimenté doit colmater toute fuite, vérifier la présence d'autres fuites, puis se charger d'allumer l'appareil pour vous. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 30
Pour régler la hauteur du tube de combustion de lÊappareil de chauffage, tournez le bouton de la vis de réglage dans le sens anti-horaire et soulevez le tube de combustion à la position désirée. Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 31
85 000 BTU/H (33,4 kW) 125 000 BTU/H (49,1 kW) Utilisez un extracteur de liquide et un vaporiseur TEMPÉRATURE DE L'AIR - ºF (ºC) TEMPÉRATURE DE L'AIR - ºF (ºC) Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 32
SCHÉMA DE CÂBLAGE WIRING DIAGRAMS PA60QFAV & PA85QFAV WIRING DIAGRAMS PA125QFAV 26168 27933 Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 33
Appareil de chauffage à air pulsé au gaz propane pour chantier de construction • modèle PA60QFAV REF.# ITEM# DESCRIPTION QTY. REF.# ITEM# DESCRIPTION Poignée 27925 Module d'allumage/de relais 23276 Garde, arrière, assemblage 27443 23045 Support, allumage 40701 Support, montage du moteur...
Page 34
Valve, variable, assemblage 27489 27449 Enveloppe exterieure 27285 Valve, gaz, principal 40900 Titulaire de orifice Ftg, connecteur mâle 26127 27487 Orifice 27493 Tuyaux et du régulateur (10 'Long) Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 35
Assemblage du tube de combustible 21036 Cordon dÊalimentation Support, allumage 23045 Passe-fil 26223 23276 Conseil, ignition d'etincelle 27493 Tuyaux et du régulateur (10 'Long) 25026 Bouton d'elevation Mr. Heater, Inc.| Forced Air Propane Construction Heater Operating Instructions and OwnerÊs Manual...
Page 36
Si une pièce est endommagée ou manquante, téléphonez à notre service de soutien technique au 800-251-0001. Adressez toute réclamation relative à la garantie à Service Department, Mr. Heater, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 États-Unis. Indiquez vos nom, adresse et numéro de téléphone ainsi que les détails de la réclamation.