The oil tray is at the bottom of the lower module. The heavy oil and fat flow during cooking
meat on the contact grill in the oil receiver from the bottom of the griddle plate.
Lift the upper module panel to get a sandwich and other ready meals.
If the temperature is a little lower, the temperature controller can automatically connect
the power supply. The heating tubes start working again to heat the griddle plates.
When the operation is complete, the temperature controller should be turned off. Turn
off the equipment and turn off the power supply.
Note: A temperature limiter is on the bottom side of the case, the trigger temperature is
130℃, and the restart temperature - ‹ 40℃. If the temperatures are higher, a safety button is
activated to provide protection. When using again, please, press the safety button first.
6.
Cleaning and maintenance
Turn off the power supply before cleaning to avoid an accident.
Do not use a wet towel with non-corrosive cleaner to clean the griddle plate, equipment
surface and power cable. It is not allowed to wash the equipment with water, otherwise it may
be damaged.
If the equipment is not used, turn off the temperature controller and main switch.
When the equipment is cleaned after operation, it may be stored in a ventilated area
without corrosive gases.
7.
Troubleshooting
Faults
1.
The griddle plates do
not heat up when the
power and heating
indicator are on.
2.
The power is
connected, the
temperature
controller and the
heating indicator are
on but the
temperature cannot
be adjusted.
3.
The indicator is not
on when the power
supply is connected
and the heating
process is not
disturbed.
4.
The indicator does
not work when
electricity is
connected.
All manuals and user guides at all-guides.com
Cause
1. The temperature
controller is
broken.
2. At least, one of the
filament heaters
has burned.
3. The temperature
fuse is activated.
1. The temperature
controller is not
workable.
1. The indicator is
broken.
1. There is no
suitable power
supply or power is
cut-off.
2.
The fuse has
Solution
1. Replace the temperature
controller.
2. Replace the burnt heating tube.
3. Remove the bottom plate and
reset the temperature fuse
manually.
1. Replace the temperature
controller.
1. Replace the temperature
controller.
1. Check if the power supply is
normal and if the connection is
correct.
2. Replace the fuse.
EN
15