Hints
▪ Do not inflate objects to a pressure for which they are not intended.
Do not pump up larger objects such as lorry tyres, tractor tyres or
inflatable boats. These exceed the permissible operating range of
the compressor account of the long pumping time. In such a case
use an inflator to complete the desired air.
▪ Please keep in mind that smaller items such as volley- or footballs
are filled very quickly. Always check the pressure and read the
operating notes by the manufacturer for these objects.
▪ Do not leave the compressor unattended while it is in operation.
▪ Do not use the compressor for more than 5 minutes continuously
and allow it to cool down for at least 15 minutes.
Cleaning and Maintenance
▪ Before undertaking any cleaning or maintenance, please pull the
power plug and allow the unit to fully cool down.
▪ Use only a damp cloth to clean the unit. Do not use aggressive
chemicals or abrasives.
Technical Data
Power Supply
Nominal Current Consumption
Fuse in Plug
Measuring Range Tolerance
Short Time Operation
Max. Pressure
Power Cable
Weight
Dimensions (L x B x H)
Start-Up and Operation
12 V Direct Current
max. 10 Ampere
6.3 x 30 mm F10 A
± 0.34 bar (5 PSI)
max. 5 min., cool down for 15 min.
18 Bar
2.85 m
1263 g
approx. 260 x 165 x 80 mm