e) Starting and using App "Im Scope"
• Search for the App "Im Scope" that you installed before and start it.
• Tap on the book symbol on the right.
• Under "Name of the camera" you can change the name of the microscope camera, if required
(Basic setting e.g. "I'm Scope Camera").
• Under "Number of photos to take at once" you can choose how many images are taken
during each saving process (selectable: (1, 3, or 5 images). These images are saved as
usual in the integrated recording folder (as with conventional photos too).
• Tap on the iPad screen 2x to save an image. A brief confi rmation will appear on the display.
f) Using the microscope camera
• With the knurled wheel (2) you can adjust the LED light continuously.
• The image can be focused using the adjustment wheel (3).
For an initial test of the microscope camera place it directly e.g. on a book page.
Set the highest brightness of the LED light using the knurled wheel (2). Afterwards,
turn the adjustment wheel (3) slowly until a clear image appears in the display of the
iPad.
The maximum distance to focus the image is approx. 4 cm.
Handling
• Use is only permitted in dry indoor locations. The product must not get damp or
wet! There is a risk of a life-threatening electric shock!
• Never use the product immediately after it has been taken from a cold room to a
warm one. The condensation that forms might damage the product under certain
circumstances. The wall plug transformer also poses a risk for a potentially fatal
electric shock!
Allow the product to reach room temperature before connecting it to the power
supply and putting it to use. This may take several hours.
• Avoid the following adverse conditions at the installation location and during trans-
portation:
- Excessive humidity or dampness
- Extreme cold or heat, direct sunlight
- Dust or fl ammable gases, fumes or solvents
- Strong vibrations, impacts or blows
- Strong magnetic fi elds such as those found in the vicinity of machinery or loud-
speakers
• Any maintenance or repair work may only be performed by an authorised repair
shop.
Tips and Notes
Microscope camera cannot be switched on
• The installed accumulator is empty. Recharge the accumulator.
Image cannot be focused
• The maximum distance to the object is about 4 cm. With farther distance the image cannot
be focused.
No picture is shown
• Increase the brightness of the integrated LEDs.
• The maximum distance to the object is about 4 cm. With farther distance the image cannot
be focused.
Cleaning
Prior to cleaning the product, switch the product off.
Use a clean, dry, soft cloth for cleaning. Do not use aggressive cleaning agents as these
can cause discolouration. Do not press too strongly on the surface when cleaning, to prevent
scratch marks.
Dust can easily be removed from the objective lens with a clean, long-haired brush and a
vacuum cleaner.
Declaration of Conformity (DOC)
We, Conrad Electronic, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this
product conforms to the fundamental requirements and the other relevant regulations of the
directive 1999/5/EC.
The Declaration of Conformity for this product can be found at www.conrad.com
All manuals and user guides at all-guides.com
Disposal
Technical Data
a) Microscope camera
Suitable for ........................... iPad (iOS from 5.1.1 is recommended)
Power supply ........................ internal LiPo accumulator (1,400 mAh), not replaceable
Operating time ...................... up to 3 h
Sensor .................................. CMOS, 1600 x 1200
Zooming ................................ approx. 500 x
Object illumination ................ 4 white LEDs, brightness adjustable
Data transfer ......................... integrated WLAN access point, 2.4 GHz
Dimensions (L x Ø) ............... 157 x 54 mm
Weight .................................. 136 g
b) Wall plug transformer
Operating voltage ................. 100 - 240 V/AC, 50/60 Hz
Output ................................... 5 V/DC, 2 A
Please dispose of the device when it is no longer of use, according to the current
statutory requirements.
Of course, the microscope camera also works with an iPhone. However, here the
displayed image is very small. For this reason, we recommend you to use the
microscope camera with an iPad only.
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2012 by Conrad Electronic SE.

Publicité

loading

Ce manuel est également adapté pour:

19 28 11