To disarm the system: In arm mode enter pass code then press the [ON/OFF], the unit will sound a long 
BEEP. The unit is now disarmed. 
 
To use the BY‐PASS mode: When the alarm is armed, if you wish to pass through the DOOR/GATE without 
disarming the unit, enter pass code and press the [by‐pass] button. This will disarm the unit for 15 seconds 
allowing you to pass through the gate or door and close it. If the door or gate remains open for 15 seconds the unit 
will sound two loud Beeps to remind you that door or gate is not closed. The unit will sound two loud Beeps every 
15 seconds if the door or gate remains open. Once the door or gate has been closed the unit will rearm itself within 
5 seconds. If the door or gate is then re‐opened without a pass code the alarm will sound. 
 
ALARM 
When unit is armed, if DOOR/WINDOW/GATE is opened the unit will sound alarm, you must enter your 
pass code and either the [ON/OFF] or [BYPASS] button to stop the alarm. If you press the [ON/OFF] button 
you must remember to rearm the unit: if you press the [BYPASS] button the unit will rearm itself within 5 
seconds if it detects that the DOOR/WINDOW/GATE is closed. 
If at any time you enter a wrong pass code the unit will sound two loud DE DE sounds: re‐ enter pass code. 
 
LOW BATTERY 
 
When battery is low the unit will flash once per second. Replace battery immediately to maintain protection. 
 
Summary Notes:  
When alarm is activated it will ring for 10 seconds and stop for 10 seconds. It will then repeat until the alarm is 
DISARMED, BY‐PASS engaged or battery dies. 
The spacing between the 2 magnetic sensors should be no more then ¼". The alarm will sound at ½" spacing and 
over. 
Keep the unit in the armed state and use the BY‐PASS to exit. This reduces the risk of forgetting to arm the unit. 
When the unit is armed, the alarm will sound when the door is opened from the outside. Key in the pass code and 
BY‐PASS to stop. 
When the alarm is armed and TRIGGERED by opening the door, even if the door is closed again the alarm will 
continue to sound until pass code is entered and disarmed or put into By‐Pass mode. 
 
NOTE: Please preserve this manual. It contains valuable information for properly setting up and operating the system. 
Please check for updated instructions at www.idealalert.ca 
 
Thank you for your purchase: If you have any questions about setup or function of this product; please call us at 800‐
361‐2236 x230(514‐363‐1030) before returning to the point of purchase. Perhaps we can resolve your difficulty and 
eliminate future customer dissatisfaction.
All manuals and user guides at all-guides.com

Publicité

loading