TROUBLESHOOTING
Problem
Pump does not work.
Noise.
Insufficient water
displacement.
HINTS ON DISPOSAL
If there is a legal regulation for the disposal of electrical
and electronic devices in your country, this symbol
on the product or on the packaging indicates that this
product must not be disposed of with household waste.
Instead, it must be taken to a collection point for the
recycling of electrical and electronic equipment. By
disposing of it in accordance with the rules, you are
protecting the environment and the health of your
fellow human beings from negative consequences. For
information about the recycling and disposal of this
product, please contact your local authority or your
household waste disposal service.
Possible cause
No power.
Burned.
Rotor is blocked.
Running without water.
Filter housing is blocked or
shaft is broken.
Ceramic shaft or bearing:
Wearing occurs.
Impeller broken.
Flow rate valve closed.
Filter housing is clogged.
Low voltage.
Suggested solution
Plug in.
Allow device to cool down.
Clear blockages.
Plug in again and add
water.
Clean blockages after
opening.
Change the shaft or
bearing.
Change impeller.
Open the flow rate valve.
Clean blockages and
plug in.
Change to right voltage.