Télécharger Imprimer la page

Electrolux EHG 30215 Notice D'utilisation page 22

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
22 electrolux
• Loose and incorrect mains plug and sock-
et connections can make the terminal be-
come too hot.
• A qualified electrician must install the
clamping connections correctly.
• Use a strain relief clamp on cable.
• Use the correct mains connection cable
and replace the damaged mains cable
with applicable cable. Speak to your local
Service Force Centre.
• The appliance must have the electrical in-
stallation which lets you disconnect the
appliance from the mains at all poles with
a contact opening width of minimum 3
mm.
• You must have correct isolation devices:
line protecting cut-outs, fuses (screw type
Installation
Warning! The following instructions
about installation, connection and
maintenance must be carried out by
qualified personnel in compliance with
standards and local regulations in force.
Gas Connection
Choose fixed connections or use a flexible
pipe in stainless steel in compliance with the
regulation in force. If you use flexible metallic
pipes, be careful they do not come in touch
with mobile parts or they are not squeezed.
Also be careful when the hob is put together
with an oven.
Important! Make sure that the gas supply
pressure of the appliance obeys the
recommended values. The adjustable
connection is fixed to the comprehensive
ramp by means of a threaded nut G 1/2".
Screw the parts without force, adjust the
connection in the necessary direction and
tighten everything.
All manuals and user guides at all-guides.com
Disposal of the appliance
• To prevent the risk of physical injury or
1
2
3
4
Rigid connection:
Carry out connection by using metal rigid
pipes (copper with mechanical end).
"Flexible" connection with mechanical
end:
– Natural gas : connection carry out with a
fuses removed from the holder), ground
leakage trips and contactors.
damage
– Disconnect the appliance from the pow-
er supply.
– Cut off the mains cable where it con-
nects with the appliance and discard it.
– Flat the external gas pipes if there are
fitted.
– Speak to your local authorised facilities
for disposal of your appliance.
1
2
3
End of shaft with nut
Washer (additional washer is only for
Slovenia and Turkey)
Elbow
Rubber pipe holder for liquid gas (only for
Slovenia and Turkey)
flexible pipe with mechanical end which is
screwed directly on the elbow finishing the
slope of the appliance.
2
4

Publicité

loading