Fault LED (Red) — The RED indicator turns on as the inverter shuts down due to overheating,
overload, under voltage, or over voltage.
Immediately turn off all AC appliances if the FAULT LED is lit. Allow the inverter to cool
before continuing. Make sure that the ventilation vents are not blocked.
If an inverter shutdown was preceded by a buzzing sound, there may be an excessive
load in combination with a low voltage or cable problem.
AC Outlets — These outlets can supply up to 15 amps at 115V AC 60 Hz, depending on
capacity of the inverter.
High Output AC Terminals — There are three insulated terminals on the front panel of the
inverter. These terminals are for connecting 115 volt AC devices that require more than 15
amps to operate. Other uses are for connection to distributed wiring that has multiple AC
outlets. Remove 2 screws on protective cover to access terminals. Any AC output wiring
that is directly connected must comply with US National Electric Code (NEC) wiring gauge
recommendations. Facing the front panel, the terminals are:
Left
Neutral
NEUTRAL and GROUND are bonded inside the inverter to comply with the National
Electric Code (NEC) requirement that any AC source must have a neutral to ground
connection.
USB Power Port — This power port can supply 5 volts at 2.1A for charging or powering
tablets, e-readers, smartphones, and other small electronic devices.
Audible Alarm (internal to the inverter) — When the Audible Alarm makes a buzzing sound,
the inverter senses a low battery condition. The user should reduce the AC load, charge the
battery, and check the DC cable for excessive losses.
Remote Switch Connection
Wagan Tech and wagan.com are trademarks of Wagan Corporation.
User's Manual—Read before using this equipment
Middle
Ground
©2018 Wagan Corporation. All Rights Reserved.
Right
Live
8