4.1. GENERAL
z If the specified operating pressure is
exceeded, or the operating temperature
Warning
is exceeded or falls too low, the result can
be leakage and irreparable damage to the
fluid level gauge.
z Fluid level gauges must only be used for
the specified fluids.
z When used in the high temperature
range, appropriate protective gloves must
be worn to actuate the check valve.
z Banjo bolts require a seal at the reservoir
z The specified torque value for the banjo
bolt of 8 – 10 Nm must be adhered to.
z Use only appropriate tools to fit the
gauge.
z The glass tube of the FSA must be not be
subjected to direct vibration or knocks as
there is a risk of it breaking.
z Ensure that no external bending forces,
tensile forces or stresses can affect the
fluid level gauge.

Operating conditions