The coarse adjustment of the depth-of-cut should be checked by a trial cut and
corrected, if necessary.
Fine adjusting the depth of cut
After a trial cut, fine adjustment can be carried out by turning the fine adjustment knob
(1 scale mark = 0.04 mm/ 1 rotation = 1.0 mm).
d. adjusting the depth stop turret (Fig.4)
Fig. 4
e. Mount dust extraction adaptor (Fig. 5)
Fig. 5
f. Speed adjuster
(Fig.6)
Fig. 6
1. For deep cuts, it is recommended to
carry out several cuts, each with
less material removal.
2. Unplug the router and set the
depth stop turret to the desired
setting. Turn clockwise or counter-
clockwise to lower or raise the
depth stop turret.
1. Fasten dust extraction adaptor to
the base plate with the screws.
2. Fix the extraction adaptor on base
plate.
3. When vacuuming dry dust that is
especially detrimental to health or
carcinogenic, use a special vacuum
cleaner.
With the thumbwheel, the required speed
can be selected (also while running).
Min-2
low speed
3-4
medium speed
5-Max
high speed