12 FLUSHING & AERATOR CLEANING
12
12A
After installation is complete, remove Aerator Housing (12A). Turn Valve (12B)
on and allow both hot and cold water to run for at least one minute each. While
water is running, check for leaks. To clean the Aerator, disassemble Aerator
Housing (12A) by separating the Aerator Head (12C), Basket (12D) and Washer
(12E). Once parts have been cleaned, reassemble by reversing steps.
13 HANDLE AND VALVE CARTRIDGE REMOVAL
13
Turn off water supplies and relieve pressure before working
on your faucet.
Using a 3 / 32 " Allen wrench, loosen Set Screw (13A) and remove Handle
(13B). To remove Cartridge (13D), remove the Dome Cap (13C) by unscrew-
ing counter-clockwise using the valve removal tool (13E). Carefully remove
the Cartridge (13D) by pulling it straight out on stem with pliers. Reassemble
faucet by reversing steps.
12B
12E
12D
12C
13E
13D
13C
13B
13A
ENGLISH
CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store
where you purchased your faucet.
2. When replacement parts are not available, please
write or call Pfister Consumer Service (See number
below).
3. Always turn off water and relieve pressure before
working on your faucet.
NOTE: Trim Care
CLEANING INSTRUCTIONS:
For all handles and decorative finishes, use only a soft
damp cloth to clean and shine. Use of polish, detergents,
abrasive cleaners, organic solvents, or acid may cause
damage. Use of other than a soft damp cloth will nul-
lify our warranty!
SPECIAL TRIM:
Trim products which contain porcelain or other similar sub-
stances are not acceptable for public areas or commercial
use. Installation of said trim is at user's risk!
1-800-PFAUCET (1-800-732-8238)
For Toll-Free Pfaucet information call
1-800-PFAUCET (1-800-732-8238)
or visit www.pfisterfaucets.com
• Installation Support
• Care and Warranty Information