4
Capacity tables
4 - 1
Capacity Table Legend
EGSAH-D9W / EGSAX-D9W / EGSAX-D9WG
Model
Domestic hot water heating mode
According to EN16147.
Model
Application
Sound power
Rated data for certification programmes -
heating mode
·· according to ·EN14511:2018·
Entering brine temperature = ·0·°C
Average climate (design temperature: ·-10·°C )
Space heating
Colder climate (design temperature: ·-22·°C )
Space heating
Warmer climate (design temperature: ·2·°C )
Space heating
Space heating - general
Other
Model
Application
·(A)· condition (·-7·°C DB / ·-8·°C WB)
·(B)· condition (·2·°C DB / ·1·°C WB)
·(C)· condition (·7·°C DB / ·6·°C WB)
·(D)· condition (·12·°C DB / ·11·°C WB)
·(E)· condition (Tol (temperature operating
limit))
·(F)· condition (Tbiv (bivalent temperature))
Psup BUH (Capacity of integrated backup heater)
Psup (Supplementary capacity at design temperature )
Remark
·P
(Declared Heating Capacity)· according to ·EN14511:2018·
dh
·COP
(Declared COP)· according to ·EN14511:2018·
dh
Load profile
Ƞwh (Water heating energy efficiency)
Domestic hot water COP
Heat-up time
Standby power input
Reference hot water temperature
Equivalent domestic hot water volume
Measured according to ·EN12102·
Heating capacity
Power input
COP
Nominal water flow rate
Seasonal data - heating
Prated at ·-10·°C
Ƞs (Seasonal space heating efficiency)
Annual energy consumption
Prated at ·-22·°C
Ƞs (Seasonal space heating efficiency)
Annual energy consumption
Prated at ·2·°C
Ƞs (Seasonal space heating efficiency)
Annual energy consumption
Capacity control method
P
(Off mode)
off
P
(Thermostat off)
to
P
(Standby mode)
sb
Pck (Crankcase heater mode)
Pdh (Declared heating capacity)
COPd (Declared COP)
Cdh (Degradation heating)
Pdh (Declared heating capacity)
COPd (Declared COP)
Cdh (Degradation heating)
Pdh (Declared heating capacity)
COPd (Declared COP)
Cdh (Degradation heating)
Pdh (Declared heating capacity)
COPd (Declared COP)
Cdh (Degradation heating)
Tol (Temperature operating limit)
Pdh (Declared heating capacity)
COPd (Declared COP)
Wtol (Heating water operation limit)
Tbiv (Bivalent temperature)
Pdh (Declared heating capacity)
COPd (Declared COP)
EGSAH06DA9W
EGSAH10DA9W
L
-
117
[%]
-
2,82
1:43
hh:mm
26,2
W
53,0
[°C]
[l]
238,7
EGSAH06DA9W
EGSAH10DA9W
35
55
35
55
[dBa]
39,0
39,0
41,0
41,0
[kW]
3,4
3,3
5,5
5,6
[kW]
0,7
1,3
1,2
2,0
-
4,5
2,5
4,7
2,9
3
m
/h
[kW]
6,0
6,2
8,5
8,5
[%]
195
141
197
152
kWh
2447
3447
3428
4393
[kW]
6,0
6,2
8,5
8,5
[%]
197
152
205
158
kWh
2884
3820
3938
5047
[kW]
6,0
6,2
8,5
8,5
[%]
183
143
194
152
kWh
1683
2189
2244
2837
Inverter
-
0,015
[kW]
0,024
[kW]
[kW]
0,015
[kW]
0,000
Average climate (design
temperature: ·-10·°C )
EGSAH06DA9W
EGSAH10DA9W
35
55
35
55
5,57
5,46
7,67
7,45
[kW]
4,84
3,13
4,51
3,15
-
0,98
1
1
1
-
3,35
3,25
4,59
4,68
[kW]
5,36
3,81
5,43
4,09
-
0,96
1
1
1
-
2,05
2,24
2,93
2,98
[kW]
5,42
4,33
5,38
4,54
-
1
0,95
1
1
-
1,05
0,96
1,36
1,37
[kW]
4,57
3,65
5,1
4,59
-
0,9
1
0,91
0,92
-
-10
-10
-10
-10
[°C]
5,95
6,44
8,55
8,49
[kW]
4,67
2,9
4,29
2,85
-
35
55
35
55
[°C]
-10
-10
-10
-10
[°C]
5,95
6,44
8,55
8,49
[kW]
4,67
2,9
4,29
2,85
-
[kW]
9,0
9,0
9,0
9,0
[kW]
0,0
0,0
0,0
0,0
Daikin Altherma ground source heat pump
Colder climate (design temperature: ·-
22·°C )
EGSAH06DA9W
EGSAH10DA9W
35
55
35
55
3,57
3,75
4,97
5,43
5,34
3,84
5,45
3,92
1
1
1
0,98
2,17
2,28
3,05
3,32
5,18
4,32
5,49
4,58
1
1
1
0,97
1,5
1,63
2,11
2,07
5,46
4,6
5,74
4,73
0,91
0,93
0,94
1
1,15
1,01
1,19
0,98
4,73
3,99
4,64
3,82
0,9
0,91
0,91
0,91
-22
-22
-22
-22
5,95
6,44
8,55
8,49
4,67
2,9
4,29
2,89
35
55
35
55
-22
-22
-22
-22
5,95
6,44
8,55
8,49
4,67
2,9
4,29
2,89
9,0
9,0
9,0
9,0
0,0
0,0
0,0
0,0
3D122777
EGSAH-D9W / EGSAX-D9W / EGSAX-D9WG
4
23