Defect of F0 to F9 is as following:
Code
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
Attention:If any other failures occurred, which need professional tools, in order to avoid danger, the machine must be
repaired or replaced by manufacturer, other maintenance offices or professionals from similar offices.
Technical specification
Model No
Rated voltage
Rated power
Adaptor Input Voltage
Adaptor Output Voltage
Electric Floorhead Model No
Electric floor head rated power
Battery pack capacity
Charge time
14
Defect
Brushroll blocked
Battery pack nickel strip broken
Charger defect
Vacuum motor short circuit
Battery cell defect
Vacuum motor 2nd over current
protection
Vacuum motor 1st over current
protection
PCB defect or PCB leadwire
loose
Battery pack NTC abnormal
Brushroll motor short circuit
Solutions
Take out brushroll to clean
Replace or repair battery pack
Replace charger
Replace vacuum motor
Replace or repair battery pack
Replace vacuum motor
Replace vacuum motor
Replace PCB or PCB leadwire
Turn off the vacuum and turn on
again after battery pack cools down.
If error code still appears, replace
battery pack.
Replace floorhead
H10 Flex
28.8V
650W
100-240V ~ 50/60 Hz 0.8A
34.2V
0.6A
T-EB110VA
50W
3000mAh
5h