Operating Instructions
CASTOR INSTALLATION (some models)
Castor installation is recommended to avoid damage to fl oors.
1. Remove the castors from the bucket of the dehumidifi er.
2. Position the dehumidifi er on its side.
3. Locate the arrow on the bottom of the dehumidifi er and insert the castor
according to the arrow direction.
4. Slide the castor in as far as it will go. The castor will snap into place.
5. Repeat steps 1 to 4 for the other 3 castors.
CONTROL PANEL INSTRUCTIONS
NOTE: The control panel of the unit you purchased may be slightly different depending on the model number.
(2) Reset filter
button
(1) Pump
mode
Pump
mode indicator
When you push the button to change operation modes, the unit will make a beeping sound to indicate that it is
changing modes.
1. Pump Button: Press to activate pump operation. Note: make sure the pump hose is installed and that the continuous
drain hose has been removed.
2. Filter Button: This product has a check fi lter feature that is a reminder to clean the air fi lter for more effi cient oper-
ation. The check fi lter light will illuminate after 250 hours of operation. To reset this function after cleaning the fi lter,
press the reset fi lter button and the light will go off.
3. Fan button: Controls the fan speed. Press to select either high (turbo) or normal fan speed. Set the fan control to
high for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the
fan control back to normal.
4. Power Button: Press to turn the dehumidifi er on or off.
5. (+ / -) Buttons: The humidity level can be set within a range of 35% RH (Relative Humidity) to 85% RH in 5% incre-
ments using these buttons. For drier air, press the (-) button and set to a lower percentage value (%). For more damp
air, press the (+) button and set a higher percentage value (%).
6. Timer Button: Press to initiate the auto-start and auto-stop feature. Set a start or stop time from 0.0 to 24 hours using
the (+) and (-) keys.
7. Display: Shows the actual (± 5% accuracy) room humidity level in a range of 30% RH to 90% RH. Otherwise, dis-
plays selection when programming humidity or timer.
To activate Continuous Dehumidifying, press the (-) button until 35% RH is set, then hold the (-) button until the contin-
uous indicator lights up. To cancel press the (+) button and reset the RH.
Note: The fan does not shut off the moment you remove the bucket, the fan will shut off after 2-3 minutes.
Check filter
light
Bucket full
(6)
Auto on
Timer button
indicator
light
(5)
Up and
down buttons
5
(7)Display
Turbo fan speed
indicator
Auto off
Auto defrost
indicator light
(3) Fan button
Continuous Dehumidifying
Indicator
(4) Power button