Troubleshooting
Occasionally, a minor problem may arise, and a service call may not be necessary- use this troubleshooting guide for a
possible solution. If the unit continues to operate improperly, call an authorized service depot or Danby's Toll Free Num-
ber for assistance.
PROBLEM
Dehumidifi er does
not start
Dehumidifi er does
not dry the air as it
should
Dehumidifi er runs
too much but does
not collect water
Dehumidifer runs
too much collects
water
Frost appears on
the coils
Controls cannot be
set
Fan noise
Water on fl oor
The pump opera-
tion light is blink-
ing
Tel: 1-800-26 -
POSSIBLE CAUSE
The dehumidifi er is un-
plugged
The fuse is blown/circuit
breaker is tripped
Dehumidifi er has reached
its preset level or bucket is
full
Bucket is not in the proper
position
Power failure
Did not allow enough time
to remove the moisture
Airfl ow is restricted
Dirty fi lter
The humidity control may
not be set low enough
Doors and windows may
not be closed tightly
Clothes dryer may be blow-
ing moisture-laden air into
the room
Room temperature is too
low
Need to reset controller
Area to be dehumidifed is
too large
Doors and windows are
open
Unit has been recently
turned on, or room tempera-
ture is below 5°C (41°F)
The compressor will turn
off and the fan will auto-
matically continue to run for
approx. 3 minutes at a fi xed
setting
Air is moving through the
dehumidifi er
Hose connection may be
loose
Bucket used to collect wa-
ter, but the hose is attached
The fi lter may be blocked
There may be a kink in the
hose
(1-800-263-2629)
Make sure the plug is pushed completely into the outlet
Check the house fuse/circuit breaker box and replace the fuse or
reset the breaker
The unit turns off automatically when either condition occurs.
Change to a lower setting or empty the bucket and replace properly
The bucket must be in place and securely seated for the unit to
operate.
There is a protective time delay (up to 3 minutes) to prevent tripping
of the compressor overload. For this reason, the unit may not start
normally for 3 minutes after it is turned back on.
When fi rst installed, allow at least 24 hours to maintain the desired
dryness
Make sure there are no curtains, blinds or furniture blocking the front
or back of the dehumidifi er. See the "Location" section.
See the "Air fi lter" section
For drier air, press the ▼ button and set to a lower percent value (%)
Check that all doors, windows and other openings are securely
closed
Install the dehumidifi er away from the dryer. The dryer should be
vented to the outside.
Moisture removal is best at higher room temperatures. Lower room
temperatures will reduce the moisture removal rate. Modes are de-
signed to be operated at temperatures above 5°C (41°F)
Set to 40% RH. Allow bucket to fi ll and then empty bucket. Adjust
controller to desired % RH.
The capacity of your dehumidifi er may not be adequate
Close all doors and windows
This is normal. Frost will usually disappear within 60 minutes. See
the "Defrost" section
This is normal. Wait approximately 3 minutes and set the fan as
desired.
This is normal
Check the hose connection. See "Continuous Drain" section
Disconnect the hose if using the bucket to collect water, see "Contin-
uous Drain" section.
Clean the pump fi lter
Check that the hose has no kinks in it.
12
SOLUTION