Operating Instructions
REMOVING COLLECTED WATER
Pump drain
Pump drain
hose outlet
hose
Pump filter
Install the pump
drain hose in
the pump
outlet
To remove, press the pump outlet in
and remove the drain hose
3.
Continuous draining using a pump:
Water can be automatically emptied into a fl oor drain or suitable
drainage receptacle by inserting the supplied pump hose in to the drain
pump outlet. Ensure the continuous drain hose is not installed to the
unit and that the plastic cover is securely placed on the continuous
drain outlet. Insert the pump drain hose into the drain pump outlet en-
suring there is a depth of at least 15 mm. Once properly inserted lead
the pump hose to the fl oor drain. Once the hose is placed where water
can easily drain out, press the "Pump" button on the control panel to
activate the pump draining feature. To remove the pump hose, press
the "Pump" button again on the control panel and remove the hose in
the reverse order of installing it.
Note: It is normal for the pump to make a little bit of noise when it is
running. Ensure there are no bends or kinks in the hose that will stop
the water from fl owing freely.
Note: If the "Pump" indicator light is fl ashing that means that the pump
has failed to operate.
•
Check that the pump fi lter is clean, to check the pump fi lter, turn
the unit off and unplug it, remove the water bucket from the unit,
pull the pump down, gently pull the fi lter off and clean the fi lter if
needed. Once clean, reinstall the fi lter by reversing how it came off
and gently pushing the pump back in to place.
•
Check that the pump hose is not kinked or blocked.
•
Empty the water in the bucket.
•
If the pump hose has dropped, reinstall it.
9