Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains
cable is correctly assembled.
The hood is provided with a special power cable ; if the cable
is damaged, request a new one from Technical Service.
Mounting
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
•
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
•
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
Operation
1.
Lights ON/OFF
2.
Motor ON/OFF
When key "2" is pressed the motor passes to speed 1.
If the key is pressed during working, the hood passes to
OFF state.
3.
Speed decrease
When key "3" is pressed the speed decreases from 4
(intense) to 1.
4.
Speed increase
When key "4" is pressed with the hood in OFF state, the
hood passes to speed 1.
If the key is pressed during working, the speed increases
from 1 to 4 (intense).
The intense speed is timed. The standard timing is 5', at
the end of which the hood sets at speed 2.
To deactivate the function before the end of the time,
press key "3", the hood sets at speed 3, when key "2" is
pressed the hood turns off.
A signal on the display corresponds to each speed:
OFF: No signal
Speed 1: 1
Speed 2: 2
Speed 3: 3
Speed 4: 4 flashing
5.
Display
Grease filter signalling
The grease filter is signalled by the display with number 1
flashing after 40 hours of use.
This means that the grease filter needs to be washed.
The signalling is visible with the hood in ON state.
To eliminate the grease filter signalling, press key "2" for
more than 3", until it turns off.
The signalling can be eliminated with the hood in ON state.
Carbon filter signalling (only for filtering version)
The carbon filter is signalled by the display with number 2
flashing after 160 hours of use.
This means that the carbon filter installed must be replaced.
The signalling is visible with the hood in ON state.
To eliminate the carbon filter signalling, press key "2" for
more than 3", until it turns off.
The signalling can be eliminated with the hood in ON state.
In case both filters are signalled at the same time, numbers 1
and 2 flash on the display alternately.
The signalling can be reset by carrying out the above-
described procedure twice.
First it resets the grease filter signalling, then the carbon filter
signalling.
In the standard mode the carbon filter signalling is not active.
In case the filtering version hood is used, it is necessary to
enable the carbon filter signalling.
Activation of carbon filter signalling:
Set the hood to OFF and keep keys "2" and "3" pressed
contemporaneously for 3".
Numbers 1 and 2 flash alternately for 2".
Deactivation of carbon filter signalling:
Set the hood to OFF and keep keys "2" and "3" pressed
contemporaneously for 3".
Number 1 flashes for 2".
Temperature Alarm
The hood is equipped with a temperature sensor which
activates the motor at speed 3 in case the temperature in the
display zone is too high.
14