The control box must only be connected at the voltage stated on the label.
R
!
CONNECTION TO THE SYSTEM
Left power point:
A1: left column socket
C1: power cable.
Sequence for proper assembly of the Skala electric lift system:
1. Connect the column or leg socket to the control box. Positions A1 and A2
2. Connect the display to the control box in position B1.
3. Connect the power cable to the control box in position C1.
4. Plug the electrical system into a power socket.
5. Reset or restart the lift system.
!
The electrical system must only be connected at the voltage stated on the label.
R
!
CONEXIÓN AL SISTEMA
B
A1
A2
C
Master
Follower
column
column
SKALA SYSTEM ELECTRICAL SYSTEM
It is important to ensure that the motor cables are fixed, but not pinched, near the control
box and the columns. Fix the cable to the board with a clip, respecting the minimum
bending radius of 30 mm.
SKALA READY SYSTEM ELECTRICAL SYSTEM
It is important to ensure that the motor cables are fixed, but not pinched, near the control
box and the columns. Fix the cable to the board with a clip, respecting the minimum
bending radius of 30 mm.
Sequence for proper assembly of the Skala Ready electric lift system:
1. Connect the master and follower columns. Positions A1 and A2
2. Connect the desktop display to the master column in position B.
3. Connect the power cable to the master column in position C.
4. Plug the electrical system into a power socket.
5. Reset or restart the lift system.
Control box
Right power point:
A2: right column socket
B1: connection to
display.