STANDARD MODELS: Plug the fan's
3a.
quick connect motor cord into the
corresponding receptacle located on
the wire compartment cover. This cord
will only fit one way into the receptacles
(Figure 11).
HUMIDITY SENSING MODELS: Plug the
3b.
fan's quick connect motor cord into the
corresponding receptacle located on the
wire compartment cover. Connect the
two pin connector from the humidistat
compartment to the two pin connector
from the side of the wire compartment
cover. These cords will only fit one way
into the receptacles (Figure 11).
3c.
MOTION SENSING MODELS: Plug the fan's quick connect motor cord into the
receptacle located on the side of the wire compartment cover. Plug the 4 pin quick
connect cord from the grill into the 4 pin receptacle located on the top of the wire
compartment cover. These cords will only fit one way into the receptacles (Figure 11).
4.
Install the ceiling mounting flange to cover any gaps which exist between the housing and
the finished ceiling. Remove the two screws that connect the ceiling mounting flange to the
housing. Put sealant (not provided) on inside edge of the ceiling mounting flange to ensure
that the flange is sealed to the ceiling. Line up the screw holes in the ceiling mounting flange
with the screw holes on the inside of the housing and press flange in place so it is tight
against the ceiling. Reinstall ceiling flange mounting screws inside the housing (Figure 12).
Ceiling
Mounting
Flange
Figure 12
NOTE: If the housing is mounted too far or not far enough into the ceiling for the flange to
make a solid connection, loosen the mounting channel and adjust the housing up or down on
the rails. Once in place, fully tighten the mounting channel nuts.
STANDARD AND HUMIDITY SENSING MODELS: Install the grill by squeezing the two
5a.
ends of the springs together and installing them up into the slots on the fan's housing.
Push the grill up into position (Figure 13).
Figure 13
MOTION SENSING MODELS: Install the grill by squeezing the spring furthest from
5b.
the motion sensor together and installing it up into the slot furthest from the wire
compartment on the fan's housing. Attach the 3 pin quick connect from the motion sensor
on the grill to the harness installed in Step 2a. This cord will only fit one way into the
receptacle. Install the other spring in place and push the grill up into position (Figure 14).
6727901 Rev. E 10-16
Motion
Fan
Humidity
Figure 11
Screws
Screw Holes
www.airkinglimited.com
Figure 14
6.
Restore power and test your installation.
SECTION 7
Programming the Occupancy Sensor
1a. Setting the Occupancy Time Delay. This will set the amount of
time the fan will continue to operate after the room is vacated.
Locate the motion sensor on the fan's grill and press the button 2
times. The LED on the sensor will then flash the number of times
to indicate the current setting, this will repeat 3 times:
1 time = 30 seconds
2 times = 2.5 minutes 6 times = 12.5 minutes
3 times = 5 minutes
7 times = 15 minutes
4 times = 7.5 minutes 8 times = 17.5 minutes
5 times = 10 minutes 9 times = 20 minutes
1b. To adjust the setting, while the sensor is still flashing from Step 1a, press the button the
number of times that corresponds with the amount of time you desire, for instance 3 times
sets the delay to 5 minutes (see numbers in Step 1). The sensor will then flash the number
of times for the new setting 3 times before exiting back to the programming mode.
2a Setting the Minimum On Time. This sets the minimum time the fan will operate once
motion is detected within the room. This works in conjunction with the Occupancy Time
Delay feature set in Steps 1a and 1b. For instance if you set the minimum time on for 15
minutes and the Time Delay for 5 minutes, the fan will operate for at least 15 minutes
then 5 additional minutes.
NOTE: This is a minimum time that the fan will operate. If the room is occupied longer, the
fan will continue to run until the room is vacated and the occupancy time delay has elapsed.
2b. Locate the motion sensor on the fan's grill and press the button 10 times. The LED on the
sensor will then flash the number of times to indicate the current setting, this will repeat
3 times:
1 time = 0 minutes
4 times = 45 minutes
2 times = 15 minutes 5 times = 60 minutes
3 times = 30 minutes
2c. To adjust the setting, while the sensor is still flashing from Step 2b, press the button
the number of times that corresponds with the amount of time you desire, for instance
3 times sets the minimum on time to 30 minutes (see numbers in Step 2b). The sensor
will then flash the number of times for the new setting 3 times before exiting back to the
programming mode.
3.
Once all setting have been made and the sensor will return to detection mode and the
LED will flash when occupancy of the room is detected.
SECTION 8
Setting the Humidistat
This fan may be equipped with a humidity sensor that automatically turns the fan on (or to
high speed on dual speed models) when humidity is above set point and off (or back to low
speed on dual speed models) when humidity is at or below set point. If the fan is operating
too long or not enough, first check to see the humidity sensor set point. In cases where the
ambient humidity level of the room rises higher than the preset level, the fan will turn on even
if the room is not occupied. This helps prevent conditions that lead to mold growth.
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE
SERVICING THE UNIT.
1.
To set the desired humidity level of the room, remove the grill and locate the
dehumidistat dial located on the wire compartment cover.
2.
Set the dial to the relative humidity you want the fan to maintain usually between 50 &
80%. Moist climates will require higher settings than dry climates. When the humidity
level of the room is below this setting the fan will remain off (or low speed on dual speed
models). When the humidity level rises above this setting the fan will turn on (or to high
speed on dual speed models) and run until the humidity level falls below this setting.
3.
Reinstall the grill and restore power.
4 of 12