Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
LIN Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as
a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
WARNING:
TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT
EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO
ATTICS, CRAWL SPACES, OR GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
6728024M Rev. C 4-12
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
WARNING:
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambéing food (ie. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the size
of the surface element.
WARNING:
THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I.
II.
III. The fire department is being called.
IV.
WARNING:
DUCTWORK.
www.airkinglimited.com
Powered Liner
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
TO REDUCE THE RISK OF INJURY TO PERSONS IN
You know you have a Class ABC extinguisher, and you
already know how to operate it.
The fire is small and contained in the area where it started.
You can fight the fire with your back to an exit.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing LIN Serie

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL LIN Series Powered Liner READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS Canopy CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. NOTE : When installing the Liner outdoors, the Air King Professional Liners are approved for use in covered outdoor kitchens only. Proper duct adapters, ducting, chimneys, roof/wall caps, etc.
  • Page 3 If the included removable grease trough is not already installed within the hood, insert Ducting into the rear inside channel of the hood. Make sure the taller side of the trough is facing towards the back of the hood (Figure 8). Outlet Adapter Grease Trough Screws...
  • Page 4: Troubleshooting Guide

    CAUTION: Cleaning ALLOW BULB TO COOL BEFORE REPLACING. CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS, Changing the Lamps ETC., AS THEY MAY DAMAGE THE RANGE HOOD. Remove the lamp by turning slightly counter-clockwise and pulling out of the socket. Replace with a PAR16 medium base 45W maximum Halogen lamp.
  • Page 5: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM ALL LIN MODELS LIN34 MODELS Qty. Description Replacement Part # Qty. Description Replacement Part # Vertical Duct Adapter (300, 500, 600 CFM) 5S1136141 Lamp Holder 5S1136075 Vertical Duct Adapter (900 CFM) 5S1136142 45w PAR16 Bulb 5S1136099 Vertical Duct Adapter (1200 CFM) 5S1136143 Baffle Filter - PHGB3 5S1136079...
  • Page 6 NOTES www.airkinglimited.com 6728024M Rev. C 4-12 6 of 12...
  • Page 7: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Série LIN Revêtements alimentés LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 INSTRUCTIONS POUR L’INSTALLATION REMARQUE : Si vous avez besoin d’un support additionnel, installez une bande en bois de 2 po X .75 po entre le dos de l’armoire (mur arrière) et la hotte. En installant la bande en bois sur le AVERTISSEMENT : dos de l’armoire, localisez les goujons dans le mur pour soutenir le poids de l’armoire.
  • Page 9 Si le dalot à graisse rétractable compris n’est pas déjà installé dans la hotte, l’insérer Conduit dans le canal intérieur arrière de la hotte. Assurez-vous que le côté le plus long du dalot fait face vers l’arrière de la hotte (Figure 8). Adaptateur de sortie Dalot à...
  • Page 10: Nettoyage

    SECTION 9 Fusible Pour remplacer le fusible, tournez le bouchon de fusible situé à côté du capuchon de Maintenance connexion dans le sens inverse des aiguilles d’une montre et retirez. Référez-vous aux instructions incluses avec le ventilateur spécifique que vous avez choisi pour l’information sur AVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST le changement du fusible.
  • Page 11 TABLEAU DES PIÈCES DE RECHANGE MODÈLES LIN34 TOUS LES MODÈLES LIN # de pièce # de pièce Qté. Description de remplacement Qté. Description de remplacement Adaptateur de sortie vertical (300, 500, 600 PCM) 5S1136141 Douille 5S1136075 Adaptateur de sortie vertical (900 PCM) 5S1136142 Lampe PAR16 de 45W 5S1136099...
  • Page 12: Remarques

    REMARQUES www.airkinglimited.com 6728024M Rev. C 4-12 12 of 12...

Ce manuel est également adapté pour:

Lin58md-12

Table des Matières