IMPORTANT INSTRUCTIONS -
Models: D4D, D4DG, D4DH, D4DGH
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6727901 Rev. E 10-16
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
h) Read all instructions before installing or using exhaust fan.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE
AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST,
STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE,
AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE
ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH
EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Publicité

loading

Sommaire des Matières pour AirKing D4D

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: D4D, D4DG, D4DH, D4DGH Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: SECTION 1 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. Preparing the Exhaust Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan.
  • Page 3 Motion Sensing Models For two speed fans wired for continuous ventilation, connect the White wire of the fan Screw to the White (Neutral) wire from the power source. Connect the ground wire from the house to the green wire from the fan housing. Connect the Black wire of the fan to the Black wire (Hot) from the power source.
  • Page 4 STANDARD MODELS: Plug the fan’s Motion quick connect motor cord into the corresponding receptacle located on the wire compartment cover. This cord will only fit one way into the receptacles (Figure 11). HUMIDITY SENSING MODELS: Plug the Humidity fan’s quick connect motor cord into the corresponding receptacle located on the wire compartment cover.
  • Page 5 SECTION 9 Fuse Follow the steps in SECTION 5 Wiring to gain access to the Setting the Speed fuse holder located inside the wire compartment. To replace This unit features a variable speed function that allows it to be set from 30 to 130 CFM. To the fuse, squeeze the top an bottom of the fuse holder together adjust the airflow: while twisting the larger piece in a direction away from the...
  • Page 6 Grill Springs 5S1202046 Ceiling Flange 5S1202050 Mounting Channel 5S1202123 Blower Assembly 5S1250100 Fuse Harness Assembly 5S1250013 Specific to Model D4D Qty. Description Replacement Part # Grill 5S1202048 Wire Compartment Assembly 5S1250102 Specific to Model D4DG Qty. Description Replacement Part #...
  • Page 7 INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modèles: D4D, D4DG, D4DH, D4DGH Ventilateur d’Évacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES SECTION 1 AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 9 Modèles avec détection de mouvement Compartiment de Câblage Extérieur : Enlever la vis du couvercle du compartiment à câblage et mettre ce couvercle dans un endroit fiable (Figure 5). Pour les ventilateurs à deux vitesses, raccordés pour une ventilation continue, connectez le fil blanc du ventilateur au fil blanc (neutre) de la source d’alimentation.
  • Page 10 MODÈLES STANDARDS: branchez le Mouvement cordon de connexion rapide du moteur du ventilateur dans la prise correspondante située sur le couvercle du compartiment de Ventilateur fil. Ce cordon ne peut être inséré que d’une seule manière dans la prise (Figure 11). MODÈLES DÉTECTEURS D’HUMIDITÉ: Humidité...
  • Page 11 SECTION 9 Fusible Suivez les étapes de la SECTION 5 Câblage pour accéder au Réglage de la vitesse porte-fusible situé à l’intérieur du compartiment de câblage. Cet appareil possède une fonction de vitesse variable qui lui permet d’être réglé de 30 à 130 Pour remplacer le fusible, pressez le haut et le bas du porte- CFM.
  • Page 12 Bride du plafond 5S1202050 Canal de montage 5S1202123 Assemblée de la Soufflante 5S1250100 Assemblage du harnais de fusible 5S1250013 Particularités de modèle D4D # de pièce de Qté. Description remplacement Grille 5S1202048 Assemblée du compartiment du fil 5S1250102 Particularités de modèle D4DG # de pièce de...

Ce manuel est également adapté pour:

D4dgD4dhD4dgh