IF YOU SMELL GAS:
• Shut o gas supply to the fire table.
• Extinguish any open flame.
• Do not try lighting any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
• Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
• WARNING
socket from the main gas supply when the fire table is not in use.
WARNING Installation and service must be preformed by a qualified installer, service agency or
•
gas supplier.
•
WARNING
Failure to follow the dangers, warning and cautions in this manual may result in
serious bodily injury or death, or in a fire or an explosion causing damage to property.
• IMPORTANT NOTICE Read and understand all warnings and precautions prior to assembly and
use of your gas fire table. Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage.
• NOTE The use and installation of this product must conform to local codes. In the absence of
local codes, use the National Fuel Gas Code, ANSI Z21.97. Reference to Natural Gas and Propane
Installation code CSA B149.1 or Propane Storage and Handling code B149.2.
• NOTE When an appliance is for connection to a fixed piping system, the installation must
conform with local codes, or in the absence of local codes with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, or International Fuel Gas Code.
•Minimum Clearance from Unit to Combustible Materials
60"(152.4cm) from the top; 48" (121.9 cm) from all sides and back. Do not locate this fire table
under any overhead enclosure.
•
Always use this outdoor fire table on a hard, level non-combustible surface such a concrete,
rock or stone. An asphalt or blacktop surface may not be acceptable for this purpose. Surfaces
such as dirt and grass may prevent the unit from having proper ventilation.
•
T
his gas
fire table and its individual shuto valve must be disconnected from the gas supply.
piping system during any pressure testing of that system at test pressures in excess of 1/2 of psi
(3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its
individual manual shuto valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psi (3.5 kPa).
• Keep these instructions for future reference. I
give this manual to him or her to read and keep for future reference.
• This gas
fire table
inside a building, garage, or any other enclosed area.
• DO NOT use this outdoor gas fire table for indoor heating. TOXIC carbon monoxide fumes can
accumulate and cause asphyxiation.
• NEVER LEAVE this gas firepit unattended when in use.
• Children should be alerted to the hazards of high surface temperatures and kept at a safe
distance while firepit is in use.
3
IMPORTANT SAFETY INFORMATION
!
WARNING FIRE TABLE IS FOR OUTDOOR USE ONLY
!
WARNING NOT FOR USE WITH LIQUID PROPANE
must be used ONLY outdoors in a well-ventilated space and shall NOT be used
f you are assembling this unit for someone else,