Une carte électronique pour commander 1/2 moteurs alimentés à 24vdc conçu pour l'automation d'un portail a battant.

Publicité

Les langues disponibles

Les langues disponibles

  W orking logic
"Step-by-Step" logic (Dip 1 = OFF Dip 2 = ON)
A Start command puts into motion, a following command stops the motion, a further Start command reverses the motion (direction reverse).
"Automatic closing" (Dip 1 = ON Dip 2 = ON)
When the gate has reached opening it will automatically close after the set Pause time. A Start command supplied during the pause interrupts
work cycle and the gate doesn't close automatically. Photocell intervention during pause time reloads it, extending the period before automatic
closing.
"Condominium" logic (Dip 1 = irrelevant Dip 2 = OFF Dip 3 = irrelevant)
When the gate has reached opening it will automatically close after the set Pause time. A Start command supplied while opening is irrelevant.
A Start command supplied while closing provokes the stop and gear reverse after approx. 1,5 sec.. A Start command or Photocell intervention
during pause time reloads it, extending the period before automatic closing. .
WARNING: after each modification of the working logic, switch the control unit off and on again to make the change active.
"Single leaf" operation (set DP3=ON and connect the leaf to the motor M2)
In single leaf operation, the operating logics described above remain unchanged.
Programming
Learning of remote controls
To enter a START code, press the P1 key once. To enter a PEDESTRIAN START code, press the P1 key twice. Each time the P1 key is pressed, the
DL1 led emits a short flash. After 3 seconds from the last pressure of P1, the DL1 led turns on with a steady light. Then press the key to be
memorized on the remote control. The DL1 led will switch off, indicating that the code has been memorized. If the code is not recognized, the DL1 led
stays on for 10 sec., after which it will automatically switch off.
Erasing of all memorized codes
To delete all the stored codes, keep the P1 key pressed for approx. 10 sec. until the DL1 led turns off.
Setting of pause time and the M2 motor's closing delay
the M2 motor's closing delay,
To set the pause time, press the P2 key once. To set
press the P2 key twice. Each time the P2 key is pressed, the DL1
led emits a short flash. After 3 seconds from the last pressure of P2, the DL1 led turns on with a steady light. Let pass the time corresponding to the
desired time and press again the key P2.
Programming of work time for M1 leaf
Rotate the RV1 trimmer to the maximum clockwise. Make sure the leaf M1 is completely closed. Press button P3 for about 3 sec., DL1 led will
turn on with steady light. Press the P1 key to open the M1 leaf with reduced speed. At the end of opening the M1 motor stops and the leaf starts
to close with the maximum speed. At the end of closing the leaf stops automatically.
Programming of work time for M2 leaf
Rotate the RV1 trimmer to the maximum clockwise. Make sure the leaf M2 is completely closed. Press button P3 for about 3 sec., DL1 led will
turn on with steady light. Press the P2 key to open the M2 leaf with reduced speed. At the end of opening the M2 motor stops and the leaf starts
to close with the maximum speed. At the end of closing the leaf stops automatically.
Warning: it is obligatory to install the mechanical stops on opening and closing
Electrical and mechanical features
Dimensions and Weight of card: 170 x 70 x 46 mm - 0,2 Kg
Main power supply: 230 Vac +/- 10%
Stand-by power consumption: 1 W approx.
Working temperature: from 0 to + 60 °C
Single motor maximum power: 40 W
Blinker power supply: 12 Vdc - 5 W max
Accessory power supply: 12 Vdc - 3 W max
Battery charger capacity: 0,1 A
Relay contact capacity: 30 A
Amperometric Stop regulation: from 50 to 87%
Programming of motor work time: 120 seconds max
Programming of delay in closing M2: 60 seconds max
Programming of pause time: 300 seconds max
Operating frequency: 433,92 or 868,35 MHz
DECLARATION OF CONFORMITY
Unit description: Electronic board controlling 1 or 2 motors 24 Vdc destined to swing gate automation.
Model: CTR570
Applied rules: EN 61000-6-3, EN 61000-6-1, EN 301489-1, EN 301489-3, EN 300220-2, EN 300220-1, EN 60950-1
Test laboratory : NEMKO SPA
The manufacturer declares that the above listed products comply to the norms provided for by European directives 2004/108/EC and 2006/95/EC.