Operating Instructions
ENVIRONMENTAL
TEMPERATURE
COMPRESSOR DELAY
PROTECTION
COOL MODE
DRY MODE
FAN
Environmental temperature of this unit (range of the unit) is
16°C - 35°C (60.8°F - 95°F).
When the unit is powered on for the first time there will be a 2-5 minute
delay in compressor start. If power is interrupted while the unit is still run-
ning there may also be a 2-5 minute delay.
1. Install the heat discharge pipe firmly, select a location near a door and
window, connect the heat discharge pipe to the outside and remember
to leave an air return vent in the window or door to guarantee the indoor
air returns to normal.
2. After pressing the ON/OFF button to turn on the unit press MODE to
select the cool option mode, the cool mode indicater light will turn on and
the unit will run in cooling mode.
3. Press SPEED to select desired fan speed (High/Medium/Low).
4. Turn on the unit (initial start) first, make sure unit is running in COOL
mode, the initial fan speed is set to high.
NOTE:
While COOL mode is running, in order to raise cooling effect, please:
• Close the curtains to prevent sunshine from shining into the air
conditioning room:
• Prevent setting other heat source in the room.
Close doors and windows to get the best results. Press ON/OFF to turn on
the unit and press MODE then select DRY. Cool and dry indicater lights
turn on and the unit will run in dry mode.
NOTE:
When in dry mode, the fan motor runs in low speed the compressor and
external fan motor will run continuously. Set temperature will not be dis-
played and will not beadjustable. The Discharge pipe will be unnecessary
to install.When under dehumidify mode, do not install the discharge pipe.
In order to make the water drain smoothly, please install the water pipe
(to the drainage).
Press ON/OFF to turn on the unit and select FAN by SPEED. The internal
fan motor can run in 3 speeds of High, Medium or low, set temperature will
not be displayed and will not be adjustable. High, Medium or low symbols
will be displayed in the display window according to the speed selected of
the internal fan.
8