general information
EN
1.1
rating plate / lighting instruction location
WARNING
!
Allow the appliance to cool before performing any maintenance or cleaning.
Both the rating plate and lighting instructions are attached to a cable and located behind the control panel of the
appliance. Lift the access plate and control panel up and away from the appliance. With the cable at the bulb end of
the slot, wiggle the rating plate out being careful not to tear the instructions.
1.2
mobile home installation
This appliance must be installed in accordance with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home
Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas
indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Built
in appliances are equipped with 1/4" (6.4mm) diameter holes located in the front left and right corners of the base.
Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must
be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the
appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized dealer/distributor.
note:
Conversion kits are not available for Vent Free appliances.
8
W415-1283 / F / 04.30.18
note:
Screen must be removed to access rating plate / lighting instructions.
A
C E R T I F I E D
CERTIFIED FOR / CERTIFIEE
POUR CANADA / USA
REFERENCE # 161746
THIS VENTED GAS FIREPLACE IS
NOT FOR USE WITH AIR FILTERS.
NOT FOR USE WITH SOLID FUEL.
FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS APPLIANCE
ONLY.
WARNING:
DO NOT ADD ANY MATERIAL
TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USE AS A
HEATING APPLIANCE
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS:
TOP
FLOOR
SIDES
BACK
VENT TOP
VENT SIDES & BOTTOM
VERTICAL VENT
MANTEL
TOP SIDES & BACK: PER STAND OFF SPACERS FOR FRAMING
MATERIALS. FOR FINISHING MATERIALS, SEE OWNER'S MANUAL
*MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE
MAXIMALE: 2". SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM LENGTHS.
ELECTRICAL RATING: 115V.60HZ. LESS THAN 12 AMPERES
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
This illustration is for reference only. Refer to the rating plate on the appli-
MAX SIZE:
8 1/2" X 4 3/4"
MATERIAL:
CLASS III A-2, PERMANENT LABEL, 6 MIL
ance for accurate information.
THICKNESS TOTAL, LEXAN, WATER
PROOF, NON-WATER SOLUBLE ADHE -
SIVE, CAPABLE OF WITHSTANDING A
MAXIMUM TEMPERATURE OF 175°F (79°C)
A
note:
LETTERING: BLACK LETTERING ON WHITE BACKGROUND
The rating plate must remain with the appliance at all times. It must not be
removed.
TITLE:
RATING PLATE BHD4
REVISION: A: CORRECTED ADHESIVE TEMP. LIMIT; UPDATED CSA DATE & DESCRIPTION || 09.07.17_C.L.
CONFORMS TO / CONFORME AUX: ANSI Z21.50 - 2016, CERTIFIED TO / CERTIFIÉ CSA 2.22 - 2016 VENTED DECORATIVE GAS APPLIANCE / FOYER À GAZ VENTILÉ
VENTED GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART
3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A. FOYER À
GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ EN VIGEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE SÉCURITÉ ET DE CONSTRUC-
TION DE MAISONS MANUFACTURÉE, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE
MESURES DE SÉCURITÉ CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. THIS APPLIANCE MUST BE INSTALLED IN
ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT ANSI Z223.1 OR CSA B149, INSTALLATION CODES. INSTALLER L'APPAREIL SELON LES CODES D'INSTALLATION ANSI Z223.1 OU
CSA-B149 EN VIGUER.
MODEL NATURAL GAS /
GAZ NATUREL
BHD4N
CBHD4N
CBHD4P
0-4500FT (0-1370M)
ALTITUDE / ÉLÉVATION
30,000 BTU/H
INPUT / ALIMENTATION
23,000 BTU/H
REDUCED INPUT / ALIMENTATION RÉDUITE
3.5" WATER COLUMN/D'UNE COLONNE D'EAU
MANIFOLD PRESSURE /
PRESSION AU COLLECTEUR
4.5" WATER COLUMN/D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE /
PRESSION D'ALIMENTATION MINIMALE
7.0" WATER COLUMN/D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE
PRESSION D'ALIMENTATION MAXIMAL E
67.9%
P.4
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT
0"
NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL
L'ENSEMBLE D'ÉVACUATION PROPRE À NAPOLEON. RÉFÉRER
0"
FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR
0"
RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR
L'ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BIEN
0"
INTAKE SYSTEM.
RÉINSTALLER ET RESCELLER L'ÉVENT APRÉS AVOIR ASSURÉ
3"
LE MAINTIEN DU SYSTÉME DE PRISE D'AIR.
2"
1"
DESSUS, CÔTÉS & ARRIÈRE : SELON LES ESPACEURS DE
8"*
DÉGAGEMENT POUR LES MATÉRIAUX D'OSSATURE SELON
LA MANUEL DE PROPRIÉTAIRE POUR LES MATÉRIAUX DE
FINITION. *L'EXTENSION HORIZONTALE MAXIMALE : 2".
RÉFÉRER AU MANUAL D'INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES. RÉFÉRER AU MANUEL
D'INSTALLATION DE PROPRIÉTAIRE.
SERIAL NUMBER/ NO. DE SÉRIE:
MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL","UN
COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI."
TO BE 10 PT ARIAL NARROW, BOLD FACE, UPPER CASE. SERIAL
NUMBERS TO BE ASCENDING FROM BHD4005814
CET FOYER À GAZ VENTILÉ N'EST
MODEL PROPANE /
PAS POUR L'USAGE AVEC LES
PROPANE MODÈLE
FILTRES D'AIR.
UN COMBUSTIBLE SOLIDE NE PAS
BHD4P
ÊTRÉ UTILISÉ AVEC CET APPAREIL.
UTILISER AVEC LES PORTE VITRÉES
0-4500FT (0-1370M)
HOMOLOGUÉES SEULEMENT AVEC
30,000 BTU/H
CETTE APPAREIL.
23,000 BTU/H
10" WATER COLUMN/D'UNE COLONNE D'EAU
ADVERTISSEMENT :
N'AJOUTEZ PAS À
11" WATER COLUMN/D'UNE COLONNE D'EAU
CET APPAREIL AUCUN MATÉRIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
13" WATER COLUMN/D'UNE COLONNE D'EAU
AUTRE QUE CELUI QUI EST FOURNI AVECT CET
APPAREIL PAR LE FABRICANT.
67.9%
PRODUIT DÉCORATIF: NE PAS UTILISER COMME
APPAREIL DE CHAUFFAGE
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX
COMBUSTIBLES :
DESSUS
PLANCHER
CÔTÉS
ARRIÈRE
DESSUS DU CONDUIT D'EVENT
CÔTÉS ET DESSOUS DU CONDUIT
D'EVENT
CONDUIT D'EVENT VERTICAL
TABLETTE
SPÉCIFICATIONS ÉLECTRIQUES : 115 V,
BHD4
60HZ. MOINS DE 12 AMPÈRES.
PAGE 1 OF 2
DWG #:
W385-1936
DATE:
02.28.14
20.1
0"
0"
0"
0"
3"
2"
1"
8"*
W385-1936 / A