Télécharger Imprimer la page

Continental Fireplaces CBHD4PN Manuel D'installation Et D'opération page 12

Publicité

Les langues disponibles

Les langues disponibles

venting requirements
EN
3.1
typical vent installations
When venting, the horizontal run must be kept to a
maximum of 20 feet (6m). If a 20 foot (6m) horizontal
run is required, the appliance must have a minimum
vertical rise off the appliance of 57" (144.8cm).
On all horizontal vent runs, ensure that the vent pipe does not slope downward.
* See "venting" section.
12
W415-1283 / F / 04.30.18
24" (61cm)
MAX
43" (109.2cm)
MIN PLUS
RISE*
16" min (40.6cm)
When terminating vertically, the vertical rise is a
minimum 36" (91.4cm) and a maximum 40 feet (12m)
above the appliance.
40 FT
(12m)
MAX
36"
(91.4cm)
MIN
38 1/4"
(97.2cm)

Publicité

loading