OPERATING INCIDENTS

The central unit does not start
1. Start by pressing the
ON button
- Ensure you have correctly replaced the tank (for removable tank
models) The maintenance LED (extreme right-hand side of the
control dial) flashes in red and green if the tank is badly positioned.
- Ensure that you do not have a mains power fault
- Check the circuit breaker and the fuses on the subscriber's
switchboard
YES
- Check the electrical socket
- Have you had a thunderstorm recently?
2. - Disconnect the central
unit from the mains net-
work and connect the
hose to the central unit
NO
- Start the central unit by
shaking the hose
YES
There are blockages in the centralised
vacuum cleaning network
- Check that the ducts are not blocked off
Carry out a network test, with all the vacuum inlets closed,
push the "Test" button on the unit for 3 seconds.
Green = network OK / Orange = network OK,
low leakages detected / Red = leak
=> Check the ducts then carry out a new test.
11/06/10
15:56
NO
There are blockages in the central unit
- Check that the hose or the accessory used is not
blocked off
- Check that the air inlet to the central unit is not
blocked off
There are leaks in the network
AND / OR
- Check that the vacuum inlets not
in use are well and truly closed
Carry out a duct network test:
C.Cleaner : see p.15.
12
Page 12
OPERATING INCIDENTS
The central unit stops all by itself
The central unit stops by itself without the user's desire to do so.
- Ensure that all the vacuum inlets and the skirting board dust pan are closed, then carry out
a duct network test by pressing the "Test" button on the central unit for 3 seconds.
• Green indicator light = vacuum cleaning network OK
• Orange indicator light = network OK, low leakages detected
• Red indicator light = leak => Check the network, then re-run a test
- Start the centralised vacuum
cleaning unit.
The central unit stops
- Disconnect the central unit
from the network
- Start the central unit
The central unit
does not stop
There are blockages in the ductwork or in
the accessories
- Check that the handle and the hose are not
blocked off
- Check that the ductwork is not blocked off
(carry out tests by connecting up to several
different network vacuum inlets)
The central unit operates correctly.
The central unit stops
Incident inside the central unit
- Check that the filter bag
is not full
- Check the electrical
connections
- Check that there is no 'plug'
or blockage in the central unit
13