Installing the Natural gas regulator
1.
Turn off the main gas supply valve.
2.
Disconnect 9 kg / 20 lb LP gas fuel tank (if present).
3.
Turn off all burner control valves.
4.
Remove the 9 kg / 20 lb LP gas fuel tank (if present)
from the grill cart.
5.
Use an adjustable wrench to remove the LP regulator
from the manifold.
6.
Use an adjustable wrench to install the Natural gas
regulator hose to the manifold and secure. Attach the
Natural gas regulator to the side panel inside the grill cart
with the two screws that are preassembled on the
regulator.
Make Gas Connection
1.
Before making any connections, check to ensure the
natural gas inlet pressure falls between the allowable
range of 7" W.C. / 0.25 psi and 14" W.C. / 0.5 psi. If the
NG inlet pressure does not fall within this range, contact
your local gas supplier.
2.
A combination of pipe fittings must be used to connect
the grill to the existing gas line.
The 3.05 m / 10 ft PVC flexible gas supply hose
design certified by CSA must be used.
Pipe-joint compounds suitable for use with Natural
gas must be used. Do not use Teflon®
There must be a certified manual shut-off valve in
the gas supply line near the grill for easy access.
®TEFLON is a registered trademark of Chemours.
All manuals and user guides at all-guides.com
tape.
12
3.
Connect the brass connector on one end of the 3.05 m /
10 ft PVC flexible gas supply hose to the Natural gas
pressure regulator.
4. Connect the quick connector on the other end of the 3.05
m / 10 ft PVC flexible gas supply hose to the rigid natural
gas supply pipe.
5.
Please do leak test after conversion. See page 8.
a.
The outdoor cooking gas appliance and its
individual shutoff valve must be disconnected from
the gas supply piping system during any pressure
testing of that system at test pressure in excess of
3.5 kPa / 0.5 psi.
b.
The outdoor cooking gas appliance must be
isolated from the gas supply piping system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply piping
system at test pressures equal to or less than 3.5
kPa / 0.5 psi.
Change Main Burner Valve Orifices
1.
Remove the grates and flame tamers.
2.
Remove the cotter clip that hold the burner in place.
Remove the burner from the grill by lifting the burner out.