Télécharger Imprimer la page

Balluff BES M18EG2-PSC50B-BV02-X02 Notice D'utilisation page 3

Capteur inductif

Publicité

Les langues disponibles

Les langues disponibles

Instruction manual BES M18EG2-PSC50B-BV02-X02
Technical data
Certificate number
HazLoc marking
Temperature range
EPL Gc and Class I, Division 2:
T6
T5
T4
T3
EPL Dc and Class II, Division 2 and Class III:
Rated voltage
Supply voltage
Rated current
Switching current
Electrostatic chargeable plastic housing
With reference to Class I, Div. 2:
With reference to Class II, Div.2 / Class III:
Housing material
Switching output
Switching distance
Operating point
Hysteresis
Switching frequency
Test voltage
Degree of protection [IEC 60529 Edition 2.2]
Electrical connection
Accessories
BA-S36088-GB-2021-10
CSA21CA80074905X
Class I, Division 2, Groups A, B, C, D T6...T3
Class II, Division 2, Groups F, G T75°C
Class III
Ex ec IIC T6...T3 Gc
Ex tc IIIC T75°C Dc
Class I, Zone 2, AEx ec IIC T6...T3 Gc
Zone 22, AEx tc IIIB T75°C Dc
–20 °C ≤ Ta ≤ +55 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
30 V DC
24 V DC ±10%
100 mA DC
100 mA DC
214 mm²
446 mm²
AISI 316 L / PA
PNP-Normally open
5 mm flush
0.8 Sn
< 0.1 Sn
180 Hz
1000 V DC / 60 s
IP 67
2 m PVC-cable, black, 3x AWG 22
2x nut M18x1, AISI 316
Page 2
Dok.-Nr. 947403-EN/FR-C21
Subject to modification

Publicité

loading

Ce manuel est également adapté pour:

Bes05tl