3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank. See Draining Air Tank under Maintenance.
WARNING: Risk of bursting. Water will condense in air tank. If not
drained, water will corrode and weaken the air tank causing a risk of
air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non freezing area.
MAINTENANCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure engine ON/OFF switch (C) is in the OFF position.
2. Disconnect spark plug wire.
3. Drain air tank.
4. Allow air compressor to cool down before starting service
NOTE: All compressed air systems contain maintenance parts (e.g.
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section should
be performed by an EMGLO factory service center or an EMGLO
authorized service center.
Maintenance Chart
Procedure
Daily
Check safety valve
Inspect air filter +
Drain air tank***
Check pump oil level
Change pump oil** +
Oil leak inspection
Inspect drive belt
Check drive belt tension
Check pulley/flywheel
alignment
Check for unusual noise/
vibration
Check for air leaks*
Clean compressor exterior
Engine
See engine instruction manual.
* To check for air leaks apply a solution of soapy water around joints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
** The pump oil must be changed after the first 20 hours of operation.
Thereafter, when using
EMGLO
oil every 200 hours of operation or once a year, whichever comes first.
*** Drain tanks daily or after four hours of use.
+ Perform more frequent in dusty or humid conditions.
14
Weekly Monthly
1 year or
200 Hours
X
X
X
X
X
X
X
X
X
X
X
X
Synthetic Blue compressor oil, change